WorkspaceManager_Err-MultipleTopLevelDocumentsMultiple Top-Level Documents_AD

您正在阅读的是 20. 版本。关于最新版本,请前往 WorkspaceManager_Err-MultipleTopLevelDocuments((Multiple Top-Level Documents))_AD 阅读 21 版本
 

Parent category: Violations Associated with Documents

Default report mode:

Summary

This violation occurs in hierarchical designs when two or more schematic sheets are at the top-level of the structure.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed in the Messages panel in the following format:

Multiple top level documents: <SheetName> has been used

where:

  • SheetName is the name of the schematic document currently being used as the top-level sheet.

Recommendation for Resolution

This issue typically arises due to the sheet symbol on the true top sheet not targeting the intended sub-sheet correctly. To resolve this issue, first determine which schematic sheet is the intended sub-sheet. Check to see if a sheet symbol has been placed for the intended sub-sheet on the top-level schematic:

  • If a sheet symbol does not exist, create it - either by manual placement or by using the Create Sheet Symbol From Sheet command (available from the main Design menu).
  • If the sheet symbol exists, ensure that it references the sub-sheet. Check the entry in the sheet symbol's File Name field in the Properties section on the General tab of the Properties panel (when the sheet symbol is selected in the workspace). The target document itself is specified in the Source section (on that same tab of the panel) with the source set to Local for a standard sheet symbol.

Upon recompiling, the hierarchy will be resolved and the error will disappear from the Messages panel.

Tip

  • Object hints will only appear provided the Enable Connectivity Insight option is enabled on the System - Design Insight page of the Preferences dialog. Use the controls associated with the Object Hints entry in the Connectivity Insight Options region of the page to determine the launch style for such hints (Mouse Hover and/or Alt+Double Click). 
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content