WorkspaceManager_Err-NetParametersWithNoNameNet Parameters with no Name_AD

您正在阅读的是 20. 版本。关于最新版本,请前往 WorkspaceManager_Err-NetParametersWithNoName((Net Parameters with no Name))_AD 阅读 21 版本
 

Parent category: Violations Associated with Nets

Default report mode:

Summary

This violation occurs when a parameter set object is attached to a net object (wire or bus) and at least one of the defined parameters in the set has no name assigned to it.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Invalid net-parameter name at <Location>

where:

  • Location is the X,Y coordinates for the hotspot of the parameter set object associated to the net.

Recommendation for Resolution

Access the Parameters dialog for the offending parameter set object and ensure that all parameters defined within have a name assigned to them. If the offending constituent parameter is not required, simply remove it from the set.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content