WorkspaceManager_Err-AddingItemsFromHiddenNetToNetAdding Items from Hidden Net to Net_AD

您正在阅读的是 20. 版本。关于最新版本,请前往 WorkspaceManager_Err-AddingItemsFromHiddenNetToNet((Adding Items from Hidden Net to Net))_AD 阅读 21 版本
 

Parent category: Violations Associated with Nets

Default report mode: 

Summary

This violation is related to components and occurs when you have specified one or more pins to be hidden and connected to an existing net within the design - typically a power pin connected to VCC or GND for example.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed the Messages panel in the following format:

Adding items to hidden net <NetName>

where:

  • NetName is the name of the target net.

Recommendation for Resolution

The problem arises when the following property for the offending pin(s) is evident in the associated Component Pin Editor dialog:

  • The Show option is disabled.

Resolution of this issue is on a per-component basis and also depends on whether a component contains multiple sub-parts.

For a non-multi-part component, enable the display of the pin(s) in the workspace (enable the Show option). You will need to wire each pin to the appropriate power port for the net to which you want to connect.

The previous solution can also be applied to multi-part components, but a far better solution is to set the Part Number field to 0. Leave the Show option for the pin disabled. Repeat for each pin that has been connected to a power net in this way. Ideally, the power net connections should be assigned through use of part 0 in the source library component.

You may edit the pin(s) using the Component Pin Editor dialog.

Tip

  • Object hints will only appear provided the Enable Connectivity Insight option is enabled on the System - Design Insight page of the Preferences dialog. Use the controls associated with the Object Hints entry in the Connectivity Insight Options region of the page to determine the launch style for such hints (Mouse Hover and/or Alt+Double Click). 