WorkspaceManager_Err-MultipleTopLevelDocumentsMultiple Top-Level Documents_AD

您正在阅读的是 17.0. 版本。关于最新版本,请前往 WorkspaceManager_Err-MultipleTopLevelDocuments((Multiple Top-Level Documents))_AD 阅读 21 版本
 

Parent category: Violations Associated with Documents

Default report mode:

Summary

This violation occurs in hierarchical designs, where two or more schematic sheets are at the top-level of the structure.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Multiple top level documents: <SheetName> has been used

where:

  • SheetName is the name of the schematic document currently being used as the top-level sheet.

Recommendation for Resolution

This issue typically arises due to the sheet symbol on the true top sheet not targeting the intended sub-sheet correctly. To resolve this issue, first determine which schematic sheet is the intended sub-sheet. Check to see if a sheet symbol has been placed for the intended sub-sheet on the top-level schematic:

  • If a sheet symbol does not exist, create it - either by manual placement or by using the Create Sheet Symbol From Sheet or HDL command (available from the main Design menu).
  • If the sheet symbol exists, check the symbol's Filename field and ensure that it references the sub-sheet.

Upon recompiling, the hierarchy will be resolved and the error will disappear from the Messages panel.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。