SMT - SMD Neck-Down
Created: March 22, 2017 | Updated: September 26, 2019
| Applies to versions: 18.0, 18.1, 19.0, 19.1, 20.0, 20.1 and 20.2
Now reading version 19.0. For the latest, read: SMT - SMD Neck-Down for version 21
Rule category: SMT
Rule classification: Unary
Summary
This rule specifies the maximum ratio of the track width to the SMD pad width, expressed as a percentage.
Constraints
- Neck-Down - the percentage value for the maximum permissible ratio of track width to SMD pad width. Entering a larger value will allow for the use of greater width track.
How Duplicate Rule Contentions are Resolved
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.
Rule Application
Online DRC and Batch DRC.