SMT - SMD Neck-Down

Now reading version 16.0. For the latest, read: SMT - SMD Neck-Down for version 21
 

Rule category: SMT

Rule classification: Unary

Summary

This rule specifies the maximum ratio of the track width to the SMD pad width, expressed as a percentage.

Constraints

Default constraints for the SMD Neck-Down rule.

  • Neck-Down – the percentage value for the maximum permissible ratio of track width to SMD pad width. Entering a larger value will allow for the use of greater width track.

How Duplicate Rule Contentions are Resolved

All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.

Rule Application

Online DRC and Batch DRC.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Note

The features available depend on your Altium product access level. Compare features included in the various levels of Altium Designer Software Subscription and functionality delivered through applications provided by the Altium 365 platform.

If you don’t see a discussed feature in your software, contact Altium Sales to find out more.

Content