This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

The Import from AutoCAD (SCH) dialog
The Import from AutoCAD (SCH) dialog

Summary

The Import from AutoCAD (SCH) dialog provides controls to import graphic data from AutoCAD *.DXF or *.DWG files into the current schematic document.

Access

The dialog is accessed from the schematic editor by choosing File » Import » DXF/DWG from the main menus then choosing a *.DXF or *.DWG file from the Import File dialog.

Options/Controls

Blocks

  • Import as components – the Importer will attempt to parse AutoCAD Blocks (grouped collections of primitive objects) as singular components then add these to a Schematic Library.
  • Import as primitives the Importer will parse all AutoCAD object data, including objects in Blocks as primitive/base objects (lines, arcs, etc.).

AutoCAD to Altium NEXUS Line Width Mapping (mm)

When AutoCAD Line data uses nominal, non-numerical width definitions (Smallest, Small, etc.,), the Importer will map these to the width dimensions (in mm) specified here. The Large line width is automatically determined.

Scale

Set the AutoCAD import scaling factor to suit the target document. The associated Size text is colored red when the boundary definition of the imported graphic (reported as Size) is larger than the target Schematic sheet (Sheet size).

Source DXF/DWG files that have been created with the units set to Mils are more likely to scale at a 1:1 ratio when imported.

Locate AutoCAD (0,0) at

  • X, Y – map the zero point from the imported AutoCAD drawing to the specified X/Y point on the target schematic sheet.
  • Select – use the cursor to graphically set the import zero point on the schematic.