WorkspaceManager_Err-MultipleTopLevelDocumentsMultiple Top-Level Documents_AD

 

Parent category: Violations Associated with Documents

Default report mode:

Summary

This violation occurs in hierarchical designs when two or more schematic sheets are at the top-level of the structure.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed in the Messages panel in the following format:

Multiple top level documents: <SheetName> has been used

where:

  • SheetName is the name of the schematic document currently being used as the top-level sheet.

Recommendation for Resolution

This issue typically arises due to the sheet symbol on the true top sheet not targeting the intended sub-sheet correctly. To resolve this issue, first determine which schematic sheet is the intended sub-sheet. Check to see if a sheet symbol has been placed for the intended sub-sheet on the top-level schematic:

  • If a sheet symbol does not exist, create it - either by manual placement or by using the Create Sheet Symbol From Sheet command (available from the main Design menu).
  • If the sheet symbol exists, ensure that it references the sub-sheet. Check the entry in the sheet symbol's File Name field in the Properties section on the General tab of the Properties panel (when the sheet symbol is selected in the workspace). The target document itself is specified in the Source section (on that same tab of the panel) with the source set to Local for a standard sheet symbol.

Upon recompiling, the hierarchy will be resolved and the error will disappear from the Messages panel.

Tip

  • Object hints will only appear provided the Enable Connectivity Insight option is enabled on the System - Design Insight page of the Preferences dialog. Use the controls associated with the Object Hints entry in the Connectivity Insight Options region of the page to determine the launch style for such hints (Mouse Hover and/or Alt+Double Click). 
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
참고

Altium 제품에 접근할 수 있는 레벨에 따라 사용할 수 있는 기능이 달라집니다. 다양한 레벨의 Altium Designer Software Subscription에 포함된 기능과 Altium 365 플랫폼에서 제공하는 애플리케이션을 통해 제공되는 기능을 비교해보세요.

소프트웨어에서 논의된 기능을 찾을 수 없는 경우, Altium 영업팀에 문의하여 자세한 정보를 확인해주세요.

콘텐츠