WorkspaceManager_Err-MissingPinFoundInComponentDisplayModeMissing Pin Found in Component Display Mode_AD

This document is no longer available beyond version 21.0. Information can now be found here: Missing pin found in component display mode for version 25

 

Parent category: Violations Associated with Components

Default report mode:

Summary

This violation occurs if there is a different number of pins between graphical display modes for a part.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed in the Messages panel in the following format:

Missing Pin <Identifier> in <DisplayMode> of part <PartName>

where:

  • Identifier is used to identify the pin in question. The identifier appears in the format PartLibraryReference-Pin Designator (e.g., DIP14-8)
  • DisplayMode is the specific graphical representation mode for the part in which the missing pin has been found. A part has a Normal mode and can have up to 255 defined Alternate modes
  • PartName is the library reference for the affected part.

Recommendation for Resolution

This violation typically arises when an alternate graphical mode is defined for a component, but not all pins specified in the Normal mode have been specified for the Alternate (i.e. there must be an identical number of pins between graphical display modes).

In the source schematic library, copy the missing pins from an existing display mode into the offending display mode for the component. This can be performed directly on the schematic sheet for a part that has been placed already, but you would typically tackle the problem from within the library, then push the change across (Tools » Update Schematics).

Tip

  • Object hints will only appear provided the Enable Connectivity Insight option is enabled on the System - Design Insight page of the Preferences dialog. Use the controls associated with the Object Hints entry in the Connectivity Insight Options region of the page to determine the launch style for such hints (Mouse Hover and/or Alt+Double Click). 
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
참고

Altium 제품에 접근할 수 있는 레벨에 따라 사용할 수 있는 기능이 달라집니다. 다양한 레벨의 Altium Designer Software Subscription에 포함된 기능과 Altium 365 플랫폼에서 제공하는 애플리케이션을 통해 제공되는 기능을 비교해보세요.

소프트웨어에서 논의된 기능을 찾을 수 없는 경우, Altium 영업팀에 문의하여 자세한 정보를 확인해주세요.

콘텐츠