WorkspaceManager_Err-FloatingPowerObjectsFloating Power Objects_AD

 

Parent category: Violations Associated with Nets

Default report mode:

Summary

This violation occurs when a power port object has been detected to be floating - not electrically connected to a component - within the design. For example the power port may have been placed but is not yet wired up to the rest of the circuit.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Floating Power Object <NetName>

where:

  • NetName is the name of the net associated with the floating power port object.

Recommendation for Resolution

Ensure that the offending power port object is connected into the circuit as required. If the power port is redundant, simply delete it from the design.

Tips

  1. This message is related to the standard, single-signal power port objects. A floating bus power port object (available when the schematic is part of an FPGA project) will be flagged in the Messages panel as a Floating Net Label.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
참고

Altium 제품에 접근할 수 있는 레벨에 따라 사용할 수 있는 기능이 달라집니다. 다양한 레벨의 Altium Designer Software Subscription에 포함된 기능과 Altium 365 플랫폼에서 제공하는 애플리케이션을 통해 제공되는 기능을 비교해보세요.

소프트웨어에서 논의된 기능을 찾을 수 없는 경우, Altium 영업팀에 문의하여 자세한 정보를 확인해주세요.

콘텐츠