Query_Lang-PCBFunctions_Fields_StartLayerStartLayer_AD
Created: 10月 31, 2018 | Updated: 3月 06, 2024
| Applies to versions: 1.0, 1.1, 2.0, 2.1, 3.0, 3.1 and 3.2
現在、バージョン 1.0. をご覧頂いています。最新情報については、バージョン Query_Lang-PCBFunctions_Fields_StartLayer((StartLayer))_AD の 4 をご覧ください。
Parent page: PCB Query Functions - Fields
Summary
Returns all via objects whose left-hand layer in their Drill Pair property complies with the Query.
Syntax
StartLayer = Layer_String
Example Usage
StartLayer = 'Top Layer'
Returns all via objects whose Drill Pair property has a left-hand entry of Top Layer
.
StartLayer <> 'Signal Layer 2'
Returns all objects except for via objects whose Drill Pair property has a left-hand entry of Signal Layer 2
.
IsVia && StartLayer <> 'Internal Plane 1
'
Returns all Via objects except those whose Drill Pair property has a left-hand entry of Internal Plane 1
.
Tips
- The single quote characters (') at the start and end of
Layer_String
are mandatory. - The Drill Pair property is only defined for via objects.