Object_HasModelParameter
This document is no longer available beyond version 21. Information can now be found here: Object_HasModelParameter for version 25
Parent page: Schematic Query Functions - Membership Checks
Summary
Returns all child objects of each part object that is linked (or references) a domain model, containing a parameter object whose Parameter Name and Value properties comply with the Query.
Syntax
Object_HasModelParameter(Parent,Parameter Name : String,Value : String,CurrentModelOnly : Boolean) : Boolean/Boolean_String
The CurrentModelOnly parameter specifies whether or not the linked model (which contains a compliant parameter) has to be a Current Model of each part. When this is False, the linked model does not have to be a Current Model (but it still can be); when this is True, the linked model does have to be a Current Model.
Example Usage
Object_HasModelParameter(Parent,'Inductance A','1mH',False)
Object_HasModelParameter(Parent,'Inductance A','1mH',False) = True
Object_HasModelParameter(Parent,'Inductance A','1mH',False) = 'True'
Returns all child objects of part objects that are linked to a model that contains a parameter object whose Parameter Name property is Inductance A, and whose Value property is 1mH. That model does not have to be a Current Model of each Part (but it can be).
Object_HasModelParameter(Parent,'Coupling Factor','0.999',True)
Object_HasModelParameter(Parent,'Coupling Factor','0.999',True) = True
Object_HasModelParameter(Parent,'Coupling Factor','0.999',True) = 'True'
Returns all child objects of part objects that are linked to a model that contains a parameter object whose Parameter Name property is Coupling Factor, and whose Value property is 0.999. That model must be a Current Model of the Part.