SMT - SMD To Corner
This document is no longer available beyond version 21. Information can now be found here: SMD To Corner Rule for version 25
Rule classification: Unary
Summary
This rule specifies the minimum distance from the edge of a surface mount pad to the first routing corner.
Constraints
Distance - the value for the minimum permissible distance from the SMD pad edge to the start of the first routing corner.
How Duplicate Rule Contentions are Resolved
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.
Rule Application
Online DRC and Batch DRC, and Interactive Routing.
Notes
-
The interactive router will obey this rule by maintaining a straight pad exit trace emanating from the pad center on any allowed "entry angle" (see SMD Entry rule), at least to the distance specified.