Working with the SMD Entry Design Rule on a PCB in Altium NEXUS

This document is no longer available beyond version 4. Information can now be found here: SMD Entry Rule for version 5

Nexus message

This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

 

Rule classification: Unary

Summary

This rule specifies the direction(s) a track can enter, or exit, an SMD pad.

All design rules are created and managed within the PCB Rules and Constraints Editor dialog. For a high-level view of working with the design rules system, see Defining, Scoping & Managing PCB Design Rules.

Constraints

Default constraints for the SMD Entry rule.
Default constraints for the SMD Entry rule.

  • Any Angle – if enabled, the track can enter/exit the pad at any angle, and at any point along its edge.
  • Corner – if enabled, the track can enter/exit through a pad corner.
  • Side – if enabled, the track can enter/exit at 90 degrees on either side of the pad. The longer edge of the pad is considered the side, note that the side option is only applied if the Side length > 2x End length. For example, if the pad is 2mm x 1mm then the side option is ignored (all sides are treated as ends). If the pad is 2.1mm x 1mm then the side option is applied.

How Duplicate Rule Contentions are Resolved

All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.

Rule Application

Online DRC, Batch DRC, and Interactive Routing.

Tips

  • The rule applies to surface mount pads only, that is, a pad defined on a single copper layer.
  • The end of the pad is determined from the pad dimensions, the ends are the shorter edges.
  • Pads can always be entered from either end (the shorter edge)
  • The rule is applied on both routing out of the pad (exit) and into the pad (entry).
 
 
 
 
 
  • The rule works in harmony with the SMD To Corner design rule, configure both to ensure neat SMD routing.

    The SMD Entry rule specifies where the route is allowed to enter/exit the SMD pad, all rule checkboxes are cleared in this example animation. Use the SMD to Corner rule to define the distance to the first corner.
    The SMD Entry rule specifies where the route is allowed to enter/exit the SMD pad, all rule checkboxes are cleared in this example animation. Use the SMD to Corner rule to define the distance to the first corner.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Content