Parent page: Schematic Commands
The following pre-packaged resources, derived from this base command, are available:
Toggle Selected Sheet Entries IO Type
Applied Parameters: ObjectKind=SheetEntry
Summary
This command is used to toggle the I/O Type for all selected sheet entries, on the current schematic sheet, simultaneously and where applicable, and irrespective of sheet symbol to which they are associated.
Access
This command can be accessed in the Schematic Editor, by:
- Choosing the Edit » Move » Toggle Selected Sheet Entries IO Type command from the main menus.
- Locating and using the Toggle Selected Sheet Entries IO Type command on the Active Bar.
If the command has been recently used from the Active Bar, it will become the active/visible button. Where other commands are available, this is indicated by a triangle at the bottom-right corner of the button. Click and hold on the active button to access a menu of all associated commands for that grouping.
The command will only be available provided at least one sheet entry is currently selected on the active schematic sheet.
Use
After launching the command, the I/O Type defined for each sheet entry will be toggled, where applicable. The actual change depends on the current I/O Type as follows:
- Unspecified remains Unspecified.
- Output changes to Input.
- Input changes to Output.
- Bidirectional remains Bidirectional.