This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

Parent page: Schematic Query Functions - Fields

Summary

Returns all part and sheet symbol (managed sheet instance) objects whose Revision property complies with the Query. This is the revision of a Component Item or Schematic Sheet Item (Managed Sheet) that has been sourced and placed from a server.

This keyword is only meaningful when using parts that have been sourced from a server.

Syntax

Revision : String

Example Usage

Revision = 'CMP-00001-A.1'
Returns all part and sheet symbol (managed sheet instance) objects whose Revision property is CMP-00001-A.1.

Revision Like '*0099B*'
Returns all part and sheet symbol (managed sheet instance) objects whose Revision property includes 0099B.

Tips

  1. The Revision property is only defined for part and sheet symbol (managed sheet instance) objects.

 