Configuring PCB Fill Keepout Object Properties in Altium NEXUS
Created: ноября 14, 2019 | Updated: апреля 09, 2021
| Applies to versions: 3.0, 3.1 and 3.2
Вы просматриваете версию 3.0. Для самой новой информации, перейдите на страницу Configuring PCB Fill Keepout Object Properties in Altium NEXUS для версии 4
Parent page: Fill Keepout
PCB Editor object properties are definable options that specify the visual style, content and behavior of the placed object. The property settings for each type of object are defined in two different ways:
- Pre-placement settings – most Fill Keepout object properties, or those that can logically be pre-defined, are available as editable default settings on the PCB Editor - Defaults page of the Preferences dialog (access from the button at the top-right of the design space). Select the object in the Primitive List to reveal its options on the right.
- Post-placement settings – all Fill Keepout object properties are available for editing in the Properties panel when a placed Fill Keepout is selected in the design space.
Location (Properties panel only)
- (X/Y)
- X (first field) - the current X (horizontal) coordinate of the reference point of the fill keepout, relative to the current design space origin. Edit to change the X position of the fill keepout. The value can be entered in either metric or imperial; include the units when entering a value whose units are not the current default.
- Y (second field) - The current Y (vertical) coordinate of the reference point of the fill keepout, relative to the current origin. Edit to change the Y position of the fill keepout. The value can be entered in either metric or imperial; include the units when entering a value whose units are not the current default.
- Rotation - the fill keepout's angle of rotation (in degrees), measured counterclockwise from zero (the 3 o'clock horizontal). Edit to change the rotation of the fill keepout. Minimum angular resolution is 0.001°.
Properties
- Restricted for Layer - use the drop-down to select the restricted layer.
- Area - provides the area of the placed object.
- Length - displays the current length of the fill keepout. Edit this field to change the length within the range 0.001mil to 10000mil.
- Width - displays the current width of the fill keepout. Edit this field to change the width within the range 0.001mil to 10000mil.
Keepout Restrictions
Use this region to select which object types will be restricted by the Keepout. Deselecting an object type will cause the Keepout to allow transgressions by that type of object (not kept out) by not imposing the applicable Clearance Rule. Choices include:
- Via
- Track
- Copper
- SMD Pad
- TH Pad