Working with the Variant Manager in Altium Designer
Parent page: Design Variants
The Variant Manager is a document-based user interface that allows you to view, create, and manage design variants of your PCB design project. To access the Variant Manager, right-click the project entry in the Projects panel and select Variants or choose Project » Variants from the main menus of the schematic or PCB editor.
Working with Variants
Creating a New Variant
To add a new variant, use the Add Variant button located at the top-left of the Variant Manager when the Variants tab is active. An additional variant column with a default title will appear in the grid area as shown in the image below. All the cells of the new column will be empty, where an empty cell indicates that this component is Fitted and unchanged from the base design.
Configuring Variant Properties
To change variant options, use the Properties panel in its Variant mode, which can be accessed by right-clicking the column header of the required variant and selecting Properties.
-
Define a meaningful name for the variant using the Name field.
-
If Fabrication Variants need to be generated from the design, enable the Allow variation of fabrication outputs option. If an output job has a variant nominated for a fabrication output, and that variant does not have the option enabled, the job's variant name will be displayed in red. Note that the red variant name is simply a warning flag, and the variant-specific output files will still be generated.
If Paste Mask outputs need to be generated for a design that includes variants with 'Not Fitted' components, enable the Allow variation for paste mask option. These components will no longer have Paste Mask openings included on their pads.
-
Use the Variant's Parameters region of the panel to define the list of variant-level parameters.
Properties of a Variant
Right-click on a cell then choose Properties to open the Properties panel that displays the details of the chosen Component/Group. The Component Parameters of the variant can be edited as needed.
The parameters can also be viewed and edited by selecting a component in the grid and then expanding the Parameter region that appears at the bottom of the grid.
Defining Component Variations
Each component in the base design can be configured to be:
- Fitted – the default setting when a new variant is created.
- Not Fitted – the original component as used in the base design is not fitted/used in this variant of that design.
- Fitted with modified component parameters, such as the component's value.
- Alternate Part – completely replacing one component with another.
Changing the state of a component in a design variant can be done by clicking the component cell in the variant column and accessing the cell drop-down that offers three choices:
- (Fitted) – the original component as used in the base design is also fitted/used in this variant of that design. Note that individual parameters can also be varied for a fitted component – see below.
- Not Fitted – the original component as used in the base design is not fitted/used in this variant of that design.
-
Alternate Part – this option allows a different (alternate) part to be selected. Use the Replace dialog (which is a modal dialog version of the Components panel) to select the required alternate part. Once that part is chosen, the cell displays the alternate part's ID.
Individual parameters can be varied for a fitted or alternate component by typing in a new parameter value in the Properties panel. Click the cell of a component in the required variant column, and use the column of the selected variant in the Component Parameters region of the Properties panel in its Component for variant mode to type in a varied parameter value. For the Footprint parameter, click the cell drop-down to select a footprint if multiple footprint models are assigned to the component. A parameter value different from the base design will be shown in yellow, and the component cell in the grid area will show the component name.
Cloning a Variant
You can clone a variant using the Clone command. Right-click in the header of the variant name column and then choose the Clone option. A new column with the same data and name (appended with "Copy") will be added. You can use the Rename option to name the new column a suitable title.
Removing a Variant
To delete the variant, select the header then use the icon. The ability to delete this or all variants is also included in the right-click context menu as shown below. A dialog opens for confirmation before the deletion occurs.
Working with Groups
To facilitate the management of a large number of design variants, the Variant Manager also allows you to create groups of components from a chosen schematic sheet, sheets referenced by a chosen sheet symbol, or a chosen component class with a functional-based view of component variations. For each group, you can define one or more ‘options’, which essentially reflect some variation of one or more components in the group. Variants themselves can then be created based on these defined groups and options, with support for creating a hierarchy of variants. When it comes time to make a change, editing a value within a group option is instantly reflected in all variants that use that group option.
The workflow of working with groups is the following:
- Switch to the Groups tab using the control at the top of the Variant Manager.
-
Using the drop-down menu of the Add Group button, select a schematic document, sheet symbol, or component class for which a group should be created.
-
A new group will be listed in the left-hand pane of the Variant Manager, while the components of the selected group will be listed on the right.
Use the Add Option button to add an option for the currently selected group. An additional option column with a default title will appear in the grid area. All the cells of the new column will be empty, where an empty cell indicates that this component is Fitted and unchanged from the base design.
-
Assign a meaningful name for the newly created option by changing the default name. Click the option's column header to select it and then click the Rename button at the bottom of the grid area or right-click the header and select Rename to access the dialog to enter a new name.
-
Using the component cells in the column of the required option, configure the component variations. The process is the same as when defining component variations for a variant.
-
Add further options for the selected group by right-clicking in the grid area and selecting Add Option. Configure the new option as required.
-
In the Variants tab of the Variant Manager, the components for which a group was created will be shown under the appropriate entry in the grid area. Using the drop-down of the cell for a group entry, select an option created for this group on the Groups tab. Variations configured for the components in this group will be applied.
Notes
- When you configure variants, the settings are saved in the project file. This includes the Not Fitted state, local parameter variations to a Fitted component, and the parameter values of Alternate Parts. The Alternate Parts are stored in the file <ProjectName>.PrjPcbVariants.
- Variant columns can be pinned to show them first, at the left of unpinned columns. To pin a variant column, hover the cursor over its header and click .
- Double-click on a component or right-click then select the Cross Probe option to jump to that component on the schematic.
- Click the View Report button at the bottom left of the Variant Manager to generate a detailed variant report in HTML format using the Variants Report dialog that opens.
- When the schematic is changed, an appropriate notification is shown at the top of the Variant Manager. Click the Refresh control next to the notification to update the data in the Variant Manager.
- The Delete option found when right-clicking on a cell can be used to delete a variant, a group or an option.