Nets Containing Multiple Similar Objects
Parent category: Violations Associated with Nets
Default report mode:
Summary
This violation occurs when two or more objects of the same type (pin, port, sheet entry) and same electrical I/O specification have been detected to be connected to each other in the same parent net. For example, an Input Port
connected to an Input Port
.
Notification
If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:
Net
<NetName> contains multiple
<ObjectType> (
<ObjectList>)
,
where:
NetName is the name of the offending net.
ObjectType is the type of object that has multiple instances found in the offending net. The entry will also reflect the object's electrical type.
ObjectList is a comma-separated list of all instances of the object found in the offending net.
Recommendation for Resolution
With the violation selected in the Messages panel, use the Details region of the panel to cross probe to the offending objects. Determine if the connected objects pose a real connectivity problem and, if so, change the I/O specification for one or both objects accordingly.
If an object is redundant, remove it from the design. If an object was intended to be wired into a different part of the design and has been connected to the wrong destination (therefore, becoming part of the wrong net), ensure that it is disconnected from its current net and wired up to the correct one.
Notes
- The actual report mode used for a violation of this type is dependent upon the specific object types, their electrical I/O types, and the corresponding reporting level defined on the Connection Matrix tab of the Options for Project dialog (Project | Content | ).
- The Report Mode setting on the Error Reporting tab of the Options for Project dialog has no affect on the Report Mode setting that appears for a violation of this type in the Messages panel. It is, however, used by the Online (real-time) error reporting directly within the design workspace. Controls for the Online reporting are available on the Schematic - Compiler page of the Preferences dialog. Note that the Online error reporting for a specific object type-I/O type pairing will not be present if the individual check for that combination in the Connection Matrix has been set to
No Report
.