Configuring Schematic Library Pin Object Properties in Altium Designer

 

Parent page: Pin

Schematic Library Editor object properties are definable options that specify the visual style, content and behavior of the placed object. The property settings for each type of object are defined in two different ways:

  • Pre-placement settings – most Pin object properties, or those that can logically be pre-defined, are available as editable default settings on the Schematic - Defaults page of the Preferences dialog (access from the  button at the top-right of the workspace). Select the object in the Primitive List to reveal its options on the right.

  • Post-placement settings – all Pin object properties are available for editing in the Properties panel when a placed Pin is selected in the workspace.

            

If the Double Click Runs Interactive Properties option is disabled (default) on the Schematic - Graphical Editing page of the Preferences dialog, when the primitive is double-clicked or you right-click on a selected primitive then choose Properties, the dialog will open. When the Double Click Runs Interactive Properties option is enabled, the Properties panel will open. 
While the options are the same in the dialog and the panel, the order and placement of the options may differ slightly. 
In the below properties listing, options that are not available as default settings in the Preferences dialog are noted as "Properties panel only".

General Tab

Location (Properties panel only)

  • (X/Y) 
    • X (first field) - the current X (horizontal) coordinate of the reference point of the object, relative to the current workspace origin. Edit to change the X position of the object. The value can be entered in either metric or imperial; include the units when entering a value whose units are not the current default. 
    • Y (second field) - The current Y (vertical) coordinate of the reference point of the object, relative to the current origin. Edit to change the Y position of the object. The value can be entered in either metric or imperial; include the units when entering a value whose units are not the current default. 
  • Rotation - use the drop-down to select the rotation. Choices are: 0 Degrees90 Degrees180 Degrees, and 270 Degrees.

Properties (Properties panel only)

  • ​Designator - the numerical identifier of the pin. Each pin in a part must have a unique designator. Use  or  to determine whether the Designator for the pin is displayed or hidden (respectively) when the parent part is placed on a schematic sheet.
  • Name - use to specify an optional display name for the pin. By default, a newly placed pin will be named using the designator value. Supplying a display name is particularly useful for IC-type components where a meaningful name enables you to see quickly how the pin is being used. Use  or  to determine whether the Name for the pin is displayed or hidden (respectively) when the parent part is placed on a schematic sheet.​
  • Electrical Type - use the drop-down to set the electrical type of the pin. This is used when compiling a project or analyzing a schematic document to detect electrical connection errors (using the Electrical Rules Check feature). Available types are: InputI/OOutputOpen CollectorPassiveHiZOpen Emitter, and Power.
  • Description - enter a meaningful description of the pin, if desired.
  • Pin Package Length - enter the pin-package length. The unit will automatically be entered after you press Enter.
  • Propagation Delay -this field lists the propagation delay, which is the amount of time it takes for the head of the signal to travel from the sender to the receiver.
  • Part Number - this field is available when the pin is being added to a multi-part component. Use the up/down arrows to specify the part to which the pin is to be associated. A multi-part component also includes a non-graphical part, Part Zero. Part Zero is used for pins that are to be included in all parts of the multi-part component, for example power pins.
  • Pin Length - use to specify the length of the pin in accordance with the currently defined units of measurement. Click the color box to edit the color of the pin.

Symbols (Properties panel only)

These symbols are purely graphical. The true electrical property of the pin is determined by the entry set for the pin's Electrical Type.
  • Inside - use to optionally add a symbol to the pin on the inside of the component graphic. Choose from: No SymbolPostponed OutputOpen CollectorHizHigh CurrentPulseSchmittOpen Collector Pull UpOpen EmitterOpen Emitter Pull UpShift Left, and Open Output.
  • Inside Edge - use to optionally add a symbol to the pin on the inside edge of the component graphic. Choose from: No Symbol and Clock.
  • Outside Edge - use to optionally add a symbol to the pin on the outside edge of the component graphic. Choose from: No SymbolDotActive Low Input, and Active Low Output.
  • Outside - use to optionally add a symbol to the pin on the outside of the component graphic. Choose from: No SymbolRight Left Signal FlowAnalog Signal InNot Logic ConnectionDigital Signal InLeft Right Signal Flow, and Bidirectional Signal Flow.
  • Line Width - use this field to determine the width of the line used to draw the symbols. Choose from either Small or Smallest. This provides support for meeting GOST standards, which stipulates that these symbols should be of the same width as the line used to draw the component's symbol.
The Line Width setting will also apply to the automatic symbol used in relation to the pin's defined Electrical Type.

Font Settings (Properties panel only)

  • Designator
    • Custom Settings - enable to access the Font Settings below to customize the font.
    • Font Settings - use the controls to configure the font, font size, color, and special settings such as bold and underlining.
    • Custom Position - enable to access the controls below to customize the position.
    • Margin - enter the desired margin.
    • Orientation - use the drop-down to select the orientation.
    • To - use the drop-down to select the desired object of the designator.
  • Name
    • Custom Settings - enable to access the Font Settings below to customize the font.
    • Font Settings - use the controls to configure the font, font size, color, and special settings such as bold and underlining.
    • Custom Position - enable to access the controls below to customize the position.
    • Margin - enter the desired margin.
    • Orientation - use the drop-down to select the orientation.
    • To - use the drop-down to select the desired object of the name.

Parameters Tab

Parameters  (Properties panel only)

Use this region to manage parameters attached to the currently selected pin object. 

  • Grid - this region lists all of the parameters currently defined for the pin. Use the   icon to lock/unlock the associated parameter.
    • Name - the name of the parameter. For a rule-type parameter, this entry will be locked as Rule.
    • Value - the value of the parameter. For a rule-type parameter, the entry will reflect the rule type along with a listing of its defined constraints.
  • Font - click to open a menu to select the desired font, font size, color, and attributes to bold, italicize, etc., if desired.
  • Other - click to open a drop-down to change additional options:
    • Show Parameter Name - enable to show the parameter name within the Schematic Library editor.
    • Allow Synchronization with Database - enable to synchronize with the database. This option is used to control if the comment can be updated. By default, these options are enabled to always allow synchronization with the source library/database. You may disable this option to prevent that comment from being included in an update process.
    • X/Y - enter the X and Y coordinates desired.
    • Rotation - use the drop-down to select the rotation. Choices are: 90°180°, and 270°.
    • Autoposition - check to enable auto-positioning, meaning that the text will remain in the chosen position as the component is moved and rotated.
  • Add - click to add a parameter. Use  to delete the currently selected parameter.

If required, a pin can be hidden in the Component Pin Editor dialog.

Older designs sometimes included components with hidden power pins, which were connected to the appropriate power net. While this practice is not recommended, hidden pins can be connected by entering the net name in the Hidden Net Name field in the SCHLIB List or SCH List panels.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
참고

Altium 제품에 접근할 수 있는 레벨에 따라 사용할 수 있는 기능이 달라집니다. 다양한 레벨의 Altium Designer Software Subscription에 포함된 기능과 Altium 365 플랫폼에서 제공하는 애플리케이션을 통해 제공되는 기능을 비교해보세요.

소프트웨어에서 논의된 기능을 찾을 수 없는 경우, Altium 영업팀에 문의하여 자세한 정보를 확인해주세요.

콘텐츠