Version 18·1·11
Build: 251 Date: 29 April 2019
31545 | Data Management: Changing model assignment now works correctly when using the Nexus Server. |
31659 | Platform: Fixed an SVN connection error issue where a created SVN v1.9 file repository could not be committed to after the software has been restarted. |
Version 18·1·9
Build: 240 Date: 22 August 2018
26443 | Draftsman: Fixed an issue where, after renaming the associated PCB document, Draftsman would crash. |
26542 | Draftsman: Fixed regression where the hatching was missing on the Assembly view for not-fitted components with silkscreen graphics selected (BC: 9416). |
24616 | Draftsman: Fixed an issue where the 'Draftsman document is out of date' redundant warning message appeared during the export of a specific user’s designs (BC:9184). |
26867 | Draftsman: Fixed regression where hatching was not displayed for not-fitted component with the missing 3D body. |
27359 | Draftsman: Fixed bug where some not-fitted components were displayed on assembly views for particular user’s designs (BC:9416). |
27588 | PCB: Fixed issue where an "Access Violation" occurred during the import of a specific design with multi-part components. |
27673 | PCB: Fixed an issue where pasting a free pad or via on a polygon pour did not accept that polygon's net setting, resulting in short-circuit and clearance violations (BC:9229). |
27871 | PCB: Implemented Arc Approximation property for standalone regions. This property is available for a selected region in the Properties panel, PCB List panel, and FSO dialog. |
26784 | SCH: Fixed an issue with the Pin Mapper where incorrect mapping would occur in some particular cases. |
27900 | SCH: Fixed an issue where placing a component on a schematic sheet became slow after compilation. |
27906 | Platform: Fixed an issue where modified field values in the Properties panel (when editing objects on a SCHDOC or SCHLIB) were not being applied if the currently selected item was changed for another or deselected (BC:9641). |
25724 | Fixed regression in an interactive multi-route process where a change to the bus spacing was not being applied through the Properties panel. |
26361 | Addressed the regression in IPC Compliant Footprint Wizard where it was not possible to change (or insert) any parameters for LGA, BGA Package Layout Options while not Full Matrix selected. |
27405 | Fixed an issue where the 'Variant or safe array index out of bounds' error message appeared when accessing multidimensional arrays. |
27451 | Fixed an issue where PCB panels that were created using embedded board arrays incorrectly output the board outline ("profile") layer to ODB++. |
27672 | Fixed an issue with the Schematic Text Frame object where, when editing through the Properties panel, Tabs were being replaced with spaces when pasting text from an external editor (BC:9663). |
27708 | Fixed an issue where the |
28081 | Fixed an error "One or more errors occurred at 000000010DA15E92" in Project Releaser that was occurring during the preparation of data. |
28216 | Fixed bug where the Clone Variant duplicate UniqueID in .PrjPCB file that led to infinite ECO loop of parameters for Alternate Parts with the Same footprint. |
Version 18·1·7
Build: 191 Date: 8 June 2018
24006 | PCB: Fixed regression that caused software crash when Signal Integrity is analyzing a board containing Accordions that are using the Mitered Arcs style. |
26310 | PCB: Fixed regression that caused software crash when using the mouse wheel in the Query Builder. |
26591 | PCB: |
26639 | PCB: The Expedition Importer has been improved to more accuracy import the Board Outline shape. |
26863 | PCB: Fixed a bug where Un-Routed Net violations were not detected if primitives are connected to an isolated part of a Hatched Polygon (BC: 8999, 9396, 9458). |
25047 | Data Management: Fixed bug where team configuration changes for Managed Output Job revisions are not updated in the released project. |
26005 | Data Management: Fixed bug where certain projects show the error 'An item with the same key has already been added.' during project Release. |
26126 | Data Management: Fixed bug where a non-accessible item in a vault could cause the error 'A component named Sections_1 already exists' during project Release. |
26446 | Data Management: Fixed regression that didn't properly restrict search results to the correct |
26163 | PCAD Importer: Fixed regression in the PCAD Importer where component rotation was not set correctly. |
26641 | Expedition Importer: Fixed bug where Footprint origins were incorrectly located. |
26293 | DxDesigner Importer: Fixed several issues related to object connectivity as well as incorrect sheet sizes, multipart symbols, pin name visibility and general stability. |
27053 | Zuken CR5000 Importer: Fixed issues with importing power ports, rounded rectangle pads, oblong pads, footprints with same pads numbers and crashes with specific projects. |
26139 | Draftsman: Fixed regression where the 'Object reference not set to an instance of an object' error occurred while placing Angular dimension between two lines. |
26443 | Draftsman: Fixed a crash after the associated PCB document was renamed. |
26489 | Draftsman: Fixed regression where Draftsman reported Illegal characters in path when creating new Draftsman document from template, for example if a footprint contained characters "?\^:". |
26772 | Platform: The UI Theme 'Altium Light Gray' now has increased contrast to improve the readability and look of panels and dialogs (BC:8859). |
Version 18·1·6
Build:161 Date: 26 April 2018
Improvements and Bug Fixes
Platform
21586 | Improved handling of Windows Min/Max buttons for Windows 7 themes where Desktop Windows Manager is inactive. |
23704 | Added new Light Gray theme option (Preferences >>> System >>> View). |
24930 | Restored Project Documents option to the Projects menu. |
20961 | Fixed bug where insertion arrows retained after moving header columns throughout the application. |
22143 | Fixed bug where some Preferences menu sections were not scaled and did not fit the High DPI aspect. |
22764 | Fixed regression where the zoom did not function for an |
23358 | Fixed regression where copy and paste (Ctrl+C, Ctrl+V) were not working in the Query Helper dialog. |
23528 | Fixed bug where Choose Folder dialog could not be moved or closed when custom scaling set to 250%. |
24178 | Out of Memory exception error resolved (BC:9014). |
24423 | Fixed regression where Differences associated with Nets varied during ECO runs (BC:8744). |
24867 | Fixed bug where a filename containing '&' symbol prevented certain characters from being typed into Text String properties (BC:8988). |
25420 | Fixed occasional crash in certain situations where Altium Designer started with the License Management page open. |
20733 | Fixed issue where an invalid window handle error would occur for a panel presenting supplier data, and that panel was pinned/unpinned. |
23887 | Updated Chinese simplified localization. |
24945 | Projects panel - Added document status indicators for opened, modified and locked (BC:8696). |
19903 | Improved the Search facility to enable all results to be viewed/selected, rather than just the first 15. |
21286 | New FPGA Pin Mapping tool to compare and update any PCB component with an external Pin File (BC:2100). |
22728 | Fixed regression where Windows Taskbar did not pop up in an auto-hide mode with AD18 in focus (with Classic Windows theme) after the hide / show Altium Designer. |
23562 | Fixed regression where you could not use the Y or N shortcut key to close Confirm message dialogs. |
23849 | Fixed bug where the Script Custom button in toolbar is empty after restarting AD. |
26222 | Fixed regression where connection lines were not built and DRC Un-Routed Net constraint violations were not being reported for Power Plane Connect Style "No Connect" rules. |
Data Management
22608 | Improved Preview aspect when browsing a Footprint Item in the Explorer panel to display 'Item not found'-type message rather than blank view. |
23278 | Added options for SVN working copy formats on Data Management - Version Control Preferences page (BC:8167). |
24116 | Excel format BOM produced from an OutputJob, where the project includes variants that reference varied parameters via a DbLink, are now updated correctly when the "Include Parameters from Database" option is enabled for BOM generation (BC:1318). |
24630 | Improved speed of Repository browsing and Check Out operations. |
20681 | Fixed regression where too many clicks were required to rename files in the Storage Manager panel. |
20684 | Fixed regression where the Storage Manager did not correctly sort filenames alphanumerically. |
20696 | Fixed regression where switching between project documents in the Projects panel while Storage Manager panel was open switched the Storage Manager panel to a random panel (e.g., Outputs, Messages). |
20737 | Fixed bug where Storage Manager panel did not display "Loading" when checking the status of project files. |
20910 | Fixed bug where there was a typo (loose instead of lose) in the confirmation dialog after performing a revert through the Storage Manager panel. |
21947 | Fixed bug in Explorer panel, where parameters with long value entries were being cut-off. They are now displayed correctly. |
22871 | Fixed Regression where multiple SVN credentials request dialogs appear after Sign In. |
22915 | Fixed regression where software would open with error if the VCS Provider - SVN extension had been removed. |
23597 | Fixed regression that caused the Parts Providers Parameter Import Options to not function correctly. |
23629 | Fixed bug where a particular Digi-Key part (754-2121-1-ND) was available through Octopart, but not through the Altium Parts Provider. |
23630 | Fixed bug where Manufacturer Part Number IS25LP016D-JNLE (Digi-Key: 706-1583-ND) was not being recognized, and data not made available through the Altium Parts Provider. |
23931 | Fixed bug with bad/invalid supplier links and not actual supplier data. |
23948 | Fixed regression where sometimes an error dialog would repeat when performing an auto-backup. |
24045 | Fixed regression that caused software crash when updating Collaboration, Compare and Merge panel. |
24556 | Fixed regression where it was not possible to add or checkout projects from SVN when the folder name path depth was more than 260 symbols. |
25425 | Fixed bug in variants where No-Fit components showed on Mechanical layer 16 when using Mechanical layers 17-32 in Footprints. |
21129 | Fixed bug that caused 'Relative Path to Template File' for BOM templates to not work with Project Releaser. |
23543 | Fixed bug where parameters listing could not be scrolled using the mouse wheel, in the Part Search panel, or Add Supplier Links dialog. |
23742 | Fixed ECO failure when updating Parameters from Database for Alternative Part from DbLib (BC:8624). |
24622 | Fixed regression where an error occurred when trying to open general templates immediately after loading software and a schematic document. |
23527 | Fixed bug with Create SVN Design Repository dialog not displaying correctly when custom scaling level set to 250%. |
25394 | Fixed exception error when trying to apply an empty SVN Libraries Working folder in Preferences. |
ActiveBOM
21314 | Added ability to group grid lines by the columns in the ActiveBOM. |
23310 | New column added to the ActiveBOM Properties panel, Supplier Subtotal per Board = Unit Price * Design Quantity. Also Price per Board now reflects the actual unit cost of the design, while the Order Price continues to reflect the MOQ costs (BC 8796). |
23362 | Improved support for line numbering in an ActiveBOM. |
23821 | Added highlighting of differences in the consolidated BOM. |
24467 | Added BOM Set functionality. |
24739 | Added "Create Manual Solution" feature to ActiveBOM solutions. |
24967 | Added ComponentType and Folder parameters to the BOM. |
25626 | ActiveBOM - Improved the Up/Down button behavior in the Select Columns dialog. |
22991 | Fixed issue where ActiveBOM automatic line numbering could create duplicate line numbers. |
23989 | Fixed regression where Core-unManaged components had 'Component revision state is not defined' BOM status violation in the BomDoc. |
24343 | Fixed bug that caused inconsistencies in 'Revision Status' and 'BOM Status' in the BomDoc for managed components. |
24891 | Fixed regression where same supplier with similar SPN for different manufacturers in custom database provider were not displayed twice in the BOM supplier tile. |
25639 | Fixed bug where manual solutions were not available in version 18.0 on the BomDoc file which was created in version 17.1. |
Draftsman
23814 | Added Color property for Designators in the Board Assembly View to enable global changes to the reference designator color (BC:8755). |
21367 | Aligned features with the user-friendly interface of Altium Designer's PCB editor for features and shortcuts such as selection, zoom, arrow keys and others. |
21375 | Performance improvements to Update Board, including multi-threading, updating only used views. |
25265 | Added support for Assembly view to change all components at once in the Component Display Properties. |
25941 | The Detail View in Draftsman now draws correctly when the Drill Table symbols are changed (BC:9287). |
22411 | Fixed zooming issue when using Space Navigator and both PCB and Draftsman documents are affected at the same time. |
23647 | Fixed regression where cutting line control points could not be moved. |
23838 | Fixed regression where it was not possible to set or edit the Alias name in the BOM Properties Panel (BC:8873). |
24621 | Fixed bug where project parameters were not being shown in Draftsman documents, for projects that have defined variants. |
24700 | Fixed bug where a component with 3D bodies that extend beyond its component geometry source could occlude that part of the assembly view. |
24736 | Fixed bug with Draftsman document, where system parameters beginning with '=VersionControl' would disappear when exporting to PDF (BC:8870). |
24839 | Fixed bug in Draftsman document, where it was not possible to set or edit tolerance values in Ordinate Dimensions for some items (BC:8874). |
24845 | Fixed bug where placing any True Geometry views on a Draftsman document would result in the views being empty (no components shown). |
25120 | Fixed regression in Draftsman where the user parameter defined in sheet template was not available after loading into the .PCBDwf file. |
25133 | Fixed error when generating a PDF from a specific Draftsman document. |
25162 | Fixed the opening of a specific Draftsman document. |
25227 | Fixed case sensitivity when using .designator parameter (BC:9078). |
25248 | Fixed bug with the access violation "An item with the same key has already been added" when placing a Layer Stack Legend for particular Rigid-Flex PCB designs (BC:9039). |
25255 | Fixed bug where a PCB document containing a particular STEP model would cause an error during Update board. |
25386 | Fixed issue with the layer ordering in the Layer Stack Legend where incorrect bottom paste position is shown. |
25390 | Fixed regression where Draftsman incorrectly prompted to save document as a template (BC:8675; BC:8898). |
25411 | Draftsman now produces the same variant hatching styles in both document editor and PDF output. |
25532 | Fixed regression where placed Assembly, Drill Drawing and Fabrication View sizes would be set to incorrect values. |
Schematic
24188 | Improved performance when moving a large number of objects in the schematic. |
25440 | Restored ability to select multiple pins in schematic library using the component pin editor. |
22213 | Fixed regression that caused SCHLIB component properties to be reset in the Properties panel. |
24298 | Fixed regression that caused Update from Libraries command to fail if part has an alternate part variant. |
22998 | Fixed bug in the Properties panel (for SCH/PCB) where different types of selection were being used for the same fields. |
24802 | Fixed bug that caused an access violation if an Update from Libraries was performed, and the project was then closed without saving. |
25129 | Fixed crash when placing a Harness object that goes beyond the sheet work area. |
23581 | Improved the presentation of simulation source entries on the Mixed Sim toolbar |
21284 | Added ability to create Differential Pair class in schematic editor (BC:5151). |
18432 | Fixed bug where a "Parameter name must be unique" message appeared when trying to change characters in the Parameter Name to upper/lower case in the Properties panel. |
23549 | Fixed regression where scrollbar was not available to scroll Model File content, when defining a Sim Model. |
24312 | Fixed bug where the port orientation was wrong after using the PCAD SCH importer. |
24745 | Fixed bug that caused xDxDesigner importer to improperly import multi-part symbols. |
21902 | Fixed bug in Schematic where delay in properties loading occurred when first selecting of schematic component (when PCB editor is started). |
22286 | Fixed bug where the 'Maintain Aspect Ratio' option was not working for a placed Picture on a Multi-board Schematic document. |
21993 | Fixed regression where Point to Point Router Options dialog was missing when placing a wire on schematic in Auto Wire mode. |
23160 | Fixed bug where an exception occurred when using the Import from DXF command in a Multi-board Schematic. The command has been removed as the DXF Importer is not implemented yet. |
23510 | Fixed regression where symbol preview wasn't available in the Sim Model - General/Spice Subcircuit dialog, under the Port Map tab. |
23799 | Fixed bug where |
24322 | Fixed regression where footprint models were missing from schematic library report files. |
24827 | Fixed bug where it was not possible to edit component properties when using the same schematic document across multiple opened projects. |
PCB
17906 | Added Height constraint to imported keepouts in IDF Importer (BC:7259). |
22135 | Smart Grid Insert now works properly with the List Panel. |
22341 | Properties Panel - Added support for formulas (for location and text values, regular calculations, action with current value) (BC:8861). |
22837 | Added support for snapping to the center of holes and center of edges in 3D models (BC:548). |
23132 | Improved Confirm dialog text and controls when deleting selected objects, and all of those objects are currently locked. |
24218 | Backdrilling improved, now supports defining a back drill pair between any layer-pair, and now recognizes connections made with polygon, region and fill objects (BC:8372). |
24732 | Updated the PCB 3D view so highlighted 3D models are rendered with suitable transparency and color. |
25388 | The right mouse Edit Layer command in View Configurations Panel now works correctly. |
25113 | Advanced Snapping options have been restored to the PCB Editor (Board Properties). |
25438 | The Pads transparency setting now works correctly and affects all pad objects. |
25592 | Improved performance of SCH > PCB synchronization (Update Schematic > PCB) when Project contains multiple variants. |
15767 | Fixed bug where the extended new primitive selection using the Tab key was not displayed for polygons. |
16436 | Fixed bug where gloss did not respect other objects on the PCB when there was a gloss differential pair with a preferred long gap. |
17632 | Fixed bug where retracing a differential pair with a big width and gap created hard violations. |
17639 | PCB Import - Fixed imported OrCAD pad diameters. |
18924 | Fixed issue where AD would hang during interactive diff pair routing, when the swap to opposite route point shortcut key (9) was pressed (BC:8630). |
18988 | Fixed regression where deleting a Net Class was not in the Undo buffer. |
18994 | Fixed regression where Pad Via Library editor was opening empty when accessing an existing PVLib |
19546 | Fixed bug in Properties panel where the library status for a pad that has been unlinked from its Pad Template wasn't being change to Local. |
21186 | Fixed regression where "Resize Polygon Pour" command was not working properly. |
21574 | Fixed bug in Multi-board Assembly document, where zooming in would be considerably 'jumpy'. |
21577 | Fixed access violation that would occur when manually routing after customizing the PCB:ManualRoute command. |
21705 | Fixed 3D display issue when viewing an Embedded Board Array from Top View in Orthographic projection. |
22191 | DRC no longer reports violations between different copper objects in a custom footprint pad, if that pad is not assigned to a net (BC:1779). |
22373 | Fixed regression where cursor hangs when moving mouse to select first Slice Track point. |
22501 | Fixed bug that caused the Properties panel Snap Point location to use the wrong coordinates. |
22574 | Fixed regression where it was not possible to remove Pad/Via dependency from a PVLib, when using the Unlink button in the Properties panel. |
22635 | Fixed bug where it was not possible to edit/copy/paste the value of a locked location through the Properties panel. |
22902 | Fixed regression where the previews of components in the Update from PCB Libraries dialog and Libraries panel were not behaving as expected. |
22936 | Fixed bug where software would hang when trying to move an accordion, and the Cross Select option was enabled. |
23020 | Fixed bug where the Shift+M shortcut for toggling the Board Insight Lens was being erroneously presented in the Heads Up display. |
23028 | Fixed bug where the PCB Heads Up display was floating over the top of an external application (even if the software was minimized). |
23067 | Fixed bug where X2.exe would stop working if a PCB document was closed while interactively routing. |
23080 | Fixed regression where software would freeze after exporting to IDF on a particular board. |
23424 | Fixed regression in PCB where changing the layer during a paused interactive process - through the Properties panel - would result in next placed objects being placed on the previous layer. |
23479 | Fixed regression where, while interactively routing and changing the track width on-the-fly, there was no alert if the width needed to be clipped back to within the min/max of the associated Width rule. |
23532 | Fixed regression where xSignals with Display Override option enabled, were not being hidden when switching mode of the PCB panel (to Nets, Components, etc). |
23651 | Fixed bug where 3D measurement lines were being drawn away from the actual measured points. |
23677 | Fixed regression where Alignment option was missing for the Layer Stack Table, when viewing properties through the Properties panel. |
23681 | Fixed bug with incorrect importing of component into a Multi-board Assembly document, when component consists of similar extruded bodies. |
23768 | Fixed regression where polygons were sometimes not updating when their Net Color was being changed and the Net Color Override was toggled On or Off . |
23781 | Fixed regression where the generated Gerber layer order between .EXTREP file and the CAMtastic panel were not synchronized. |
23797 | Fixed regression where, after changing shape/size for Top-Middle-Bottom and Full Stack pads and vias on some non-Top layer, the focus in the Properties panel jumps to the Top Layer. |
23805 | Fixed regression where extruded 3D bodies with zero overall height were being displayed in 3D (in DX10). |
23837 | Fixed bug where, after changing the Rotation Step for a PCB document with an Embedded Board Array, there would be an error: 'Object reference not set to an instance of an object'. |
23899 | Fixed bug where 3D Body Opacity could not be set for multiple selected components. |
24068 | Resolved issue where a PCB lib could not be saved if an interactive process was currently being performed. |
24164 | Fixed regression where the display of PCB Library Footprint names were truncated incorrectly (BC:8692). |
24228 | Fixed bug where project parameters were not updated in Special Strings until the string was selected on PcbDoc after changing parameter value. |
24258 | Fixed regression that caused error when generating Gerber files for layers that contain zero-size primitives. |
24365 | Fixed regression where the warning message 'A command is currently active and save cannot be completed' appeared after launching interactive Diff Pair Routing or the Length Tuning command, twice. |
24399 | Fixed bug where Paste Mask Expansion option was missing for Track and Arc primitives. |
24784 | Unconnected mid layer pads are now correctly removed during Gerber and ODB++ output generation (BC:8961). |
25094 | Fixed regression where the Solder Mask is missing from OutJob PCB 3D PDF prints when Entire Board From Below option is enabled. |
25155 | Fixed controls within the Pick and Place "Custom Filter" dialog (BC:9089). |
25220 | Fixed file loading error when PCB document contained dimension objects from previous version. |
25240 | Fixed regression where Gerber Batch import would produce an access violation (BC:9112). |
25309 | Fixed regression with PCB to SCH Cross Selection and selecting multiple objects. |
25389 | PCB Defaults are now saving the Via and Pad template settings. |
25416 | Fixed incorrect component standoff heights when exporting to STEP files and using multiple layer stacks. |
25433 | Fixed crash when running PCB Design Check in CAMtastic. |
25439 | Fixed regression where the Mask option was not being applied correctly in the PCB panel. |
25462 | Fixed regression where Snap points on 3D bodies were not visible (BC:9013). |
25632 | Fixed crash in Draftsman when setting the Layer Stack Table text height to 0. |
25649 | Fixed runtime errors and "unable to save file" errors after changing Via Template using the Properties Panel and closing the PCB Rules and Constraints Editor. |
23539 | Fixed issue where it was not possible to select more than one primitive on a PCBLIB, if a BomDoc was opened in a separate window and the Cross Selection setting was enabled. |
25138 | Fixed regression where it was not possible to delete locked objects if all selected objects were locked. |
17293 | Fixed bug where it was not possible to define via shapes/sizes on each layer during changing the via shielding stack from Simple to Full Stack or Top-Middle-Bottom. |
18454 | Fixed bug where the Size and Shape properties were not available to update when selected pads had a different stack mode. |
21801 | Fixed bug where "Change Units" command did not work for the 'Snap Distance', when the value from presets has been selected. |
22397 | Fixed bug where the Opacity slider disappeared when a group of 3D Models is selected, and did not reappear when selected for editing. |
23317 | Fixed regression where the new track Width wasn't immediately applied but required a cursor move after pausing PCB routing to enter a new width. |
24268 | Fixed regression where some fonts in the Font Family were not listed in the properties panel. |
24276 | Fixed layout of Arc properties in PCB Properties panel (BC:8693). |
24363 | Fixed bug that caused changes to be applied immediately when trying to find net by Net Name. |
24617 | Fixed regression where it was impossible to un-assign testpoints on net using either the Testpoint Manager or PCB List when both Top and Bottom Testpoints were assigned to a pad, and the pad was moved to top/bottom layer. |
25434 | Fixed bug in the Width slider behavior so that it may now be moved to Min, Preferred, Max positions even when the design rules have the same values (BC:8741). |
23626 | Improved layer name visibility in the Properties panel. Short layer names are now right-aligned. |
23750 | Added TrueType Font support to PCB output PDF files so text may be searched (BC:1482). |
23789 | Added ability to do STEP output without free models by adding 'Skip free 3D bodies' option to Export Options dialog (BC:1240). |
22288 | Multi-Board: Improved behaviour of object collision test after a plane-to-plane alignment. Implemented speed improvements. |
25116 | Added option in View Configuration panel for representation of labels with Special String names in PCB (BC:8832). |
24548 | Updated IDF 3.0++ Exporter to include objects with MultiLayer. |
22090 | Fixed regression where adding an Ibis model would result in X2.exe to stop working. |
22216 | Fixed regression that caused Ctrl+Q hotkey to function when focused on Interactive Properties panel (BC: 8841). |
22896 | Fixed regression where the units were not changed in Violation Details when changing units on PCB. |
23039 | Fixed bug where changing the 3D Body Opacity for a component, through the Properties panel, caused polygon rebuilding. |
23061 | New Graphic Engine - Fixed regression to restore the zoom level to the same depth as previously possible so that very fine grids may be displayed. |
25469 | IPC Footprint Wizard now supports step model preview and generation. |
23089 | Expedition importer now detects plane layers that contain routes, these are now imported as signal layers. |
23782 | Fixed bug where summary DRC information in CAMtastic was not presented correctly. |
23818 | Fixed bug where the default rule, rather than the applicable rule, was being displayed in the Properties panel when performing interactive Diff Pair Routing. |
23853 | Fixed bug where a corrupted 3D body would result, if trying to create an extruded 3D body using Line 90/90 Horizontal Start with Arc (Radius: 100mil). |
24474 | Fixed regression where switching the View to Print in the PCB 3D Print Settings for a project created from templates after generation produces a PCB without solder mask and copper in the generated PDF. |
24492 | Fixed bug where analyzing nets for designs containing FromTos took a long period of time. |
24513 | Fixed regression where the Line Constraints dialog could not be accessed via the Tab key when slicing a Polygon Pour. |
18799 | Updated Polygon Pour options layout in Properties panel. |
23507 | Added support for the new UI theme to the IPC Compliant Footprint Wizard. |
The following sections list the release notes for publically released versions of Altium NEXUS 1.1
Version 1·1·11
Build: 89 Date: 29 April 2019
31545 | Data Management: Changing model assignment now works correctly when using the Nexus Server. |
31659 | Platform: Fixed an SVN connection error issue where a created SVN v1.9 file repository could not be committed to after the software has been restarted. |
Version 1·1·9
Build: 86 Date: 22 August 2018
26443 | Draftsman: Fixed an issue where, after renaming the associated PCB document, Draftsman would crash. |
26542 | Draftsman: Fixed regression where the hatching was missing on the Assembly view for not-fitted components with silkscreen graphics selected (BC: 9416). |
24616 | Draftsman: Fixed an issue where the 'Draftsman document is out of date' redundant warning message appeared during the export of a specific user’s designs (BC:9184). |
26867 | Draftsman: Fixed regression where hatching was not displayed for not-fitted component with the missing 3D body. |
27359 | Draftsman: Fixed bug where some not-fitted components were displayed on assembly views for particular user’s designs (BC:9416). |
27588 | PCB: Fixed issue where an "Access Violation" occurred during the import of a specific design with multi-part components. |
27673 | PCB: Fixed an issue where pasting a free pad or via on a polygon pour did not accept that polygon's net setting, resulting in short-circuit and clearance violations (BC:9229). |
27871 | PCB: Implemented Arc Approximation property for standalone regions. This property is available for a selected region in the Properties panel, PCB List panel, and FSO dialog. |
26784 | SCH: Fixed an issue with the Pin Mapper where incorrect mapping would occur in some particular cases. |
27900 | SCH: Fixed an issue where placing a component on a schematic sheet became slow after compilation. |
27906 | Platform: Fixed an issue where modified field values in the Properties panel (when editing objects on a SCHDOC or SCHLIB) were not being applied if the currently selected item was changed for another or deselected (BC:9641). |
25724 | Fixed regression in an interactive multi-route process where a change to the bus spacing was not being applied through the Properties panel. |
26361 | Addressed the regression in IPC Compliant Footprint Wizard where it was not possible to change (or insert) any parameters for LGA, BGA Package Layout Options while not Full Matrix selected. |
27405 | Fixed an issue where the 'Variant or safe array index out of bounds' error message appeared when accessing multidimensional arrays. |
27451 | Fixed an issue where PCB panels that were created using embedded board arrays incorrectly output the board outline ("profile") layer to ODB++. |
27672 | Fixed an issue with the Schematic Text Frame object where, when editing through the Properties panel, Tabs were being replaced with spaces when pasting text from an external editor (BC:9663). |
27708 | Fixed an issue where the |
28081 | Fixed an error "One or more errors occurred at 000000010DA15E92" in Project Releaser that was occurring during the preparation of data. |
28216 | Fixed bug where the Clone Variant duplicate UniqueID in .PrjPCB file that led to infinite ECO loop of parameters for Alternate Parts with the Same footprint. |
Version 1·1·7
Build: 68 Date: 8 June 2018
25047 | Data Management: Fixed bug where team configuration changes for Managed Output Job revisions are not updated in the released project. |
26005 | Data Management: Fixed bug where certain projects show the error 'An item with the same key has already been added.' during project Release. |
26126 | Data Management: Fixed bug where a non-accessible item in a vault could cause the error 'A component named Sections_1 already exists' during project Release. |
26446 | Data Management: Fixed regression that didn't properly restrict search results to the correct |
24006 | PCB: Fixed regression that caused software crash when Signal Integrity is analyzing a board containing Accordions that are using the Mitered Arcs style. |
26310 | PCB: Fixed regression that caused software crash when using the mouse wheel in the Query Builder. |
26591 | PCB: |
26639 | PCB: The Expedition Importer has been improved to more accuracy import the Board Outline shape. |
26863 | PCB: Fixed a bug where Un-Routed Net violations were not detected if primitives are connected to an isolated part of a Hatched Polygon (BC: 8999, 9396, 9458). |
26163 | PCAD Importer: Fixed regression in the PCAD Importer where component rotation was not set correctly. |
26641 | Expedition Importer: Fixed bug where Footprint origins were incorrectly located. |
26293 | DxDesigner Importer: Fixed several issues related to object connectivity as well as incorrect sheet sizes, multipart symbols, pin name visibility and general stability. |
27053 | Zuken CR5000 Importer: Fixed issues with importing power ports, rounded rectangle pads, oblong pads, footprints with same pads numbers and crashes with specific projects. |
26139 | Draftsman: Fixed regression where the 'Object reference not set to an instance of an object' error occurred while placing Angular dimension between two lines. |
26443 | Draftsman: Fixed a crash after the associated PCB document was renamed. |
26489 | Draftsman: Fixed regression where Draftsman reported Illegal characters in path when creating new Draftsman document from template, for example if a footprint contained characters "?\^:". |
26772 | Platform: The UI Theme 'Altium Light Gray' now has increased contrast to improve the readability and look of panels and dialogs (BC:8859). |
Version 1·1·6
Build: 48 Date: 26 April 2018
Altium NEXUS
19186 | Altium NEXUS - Improved performance of component update when using batch editor. |
19419 | Altium NEXUS - Request part button that appears in the Explorer and Part Search panels after a search, now calls available Part Request workflow processes. |
20493 | Altium NEXUS - Fixed bug where the 'Always Show Comment/Designator' option from document options SCHLIB was not preserved during editing. |
20494 | Altium NEXUS - Improved Single Component Editor to facilitate drag and drop of domain models directly from the Explorer panel (as per Batch Editing mode). |
20603 | Altium NEXUS - Improved usability of Managed Projects through UI and functionality updates. |
24573 | Altium NEXUS - Fixed regression where 'Load linked' function of Batch state change did not work. |
24896 | Altium NEXUS - Fixed bug that caused an access violation when navigating to specific footprint. |
21740 | Added the ability to specify the default target folders for the Single Component Editor. |
22758 | Improved performance and usability of Where-used in Explorer panel. |
23453 | Improved process and hints of uploading 3D models into server. |
23468 | Improved presentation of information when viewing the Full Item details for a managed Item. |
17718 | Fixed bug causing slow performance during some Vault operations when lots of Vault folders are loaded in the the Libraries panel. |
19127 | Fixed bug with a missing file when using "Collate outputs into a single file". |
20599 | Fixed behavior of the revision navigation, when launching Explorer panel in selection mode (via Choose.. actions etc.). |
21910 | Fixed bug where icons were appearing in place of Preferences, Notifications and User icons, when opening a Symbol or Footprint Item for editing from a source Vault. |
23175 | Fixed bug where a schematic symbol pasted from a local SCHLIB to the temporary editing window for a Symbol Item could not be released due to a 'missing lifecycle definition' error. |
23739 | Fixed regression where Design Repositories were missing after restoring Preferences. |
24023 | Fixed bug that caused slow information loading when using Where-used in Explorer panel. |
24082 | Fixed bug where running the Component Rule Check (from the Single Component Editor, while editing a managed component) would throw an error where pin/pad designator 0 was being used. Designator 0 is supported correctly now. |
24653 | Fixed bug where an incorrect information link displayed when cannot be connected to an on-premise server. |
Platform
21586 | Improved handling of Windows Min/Max buttons for Windows 7 themes where Desktop Windows Manager is inactive. |
23704 | Added new Light Gray theme option (Preferences >>> System >>> View). |
24930 | Restored Project Documents option to the Projects menu. |
20961 | Fixed bug where insertion arrows retained after moving header columns throughout the application. |
22143 | Fixed bug where some Preferences menu sections were not scaled and did not fit the High DPI aspect. |
22764 | Fixed regression where the zoom did not function for an |
23358 | Fixed regression where copy and paste (Ctrl+C, Ctrl+V) were not working in the Query Helper dialog. |
23528 | Fixed bug where Choose Folder dialog could not be moved or closed when custom scaling set to 250%. |
24178 | Out of Memory exception error resolved (BC:9014). |
24423 | Fixed regression where Differences associated with Nets varied during ECO runs (BC:8744). |
24867 | Fixed bug where a filename containing '&' symbol prevented certain characters from being typed into Text String properties (BC:8988). |
25420 | Fixed occasional crash in certain situations where Altium Designer started with the License Management page open. |
20733 | Fixed issue where an invalid window handle error would occur for a panel presenting supplier data, and that panel was pinned/unpinned. |
23887 | Updated Chinese simplified localization. |
24945 | Projects panel - Added document status indicators for opened, modified and locked (BC:8696). |
19903 | Improved the Search facility to enable all results to be viewed/selected, rather than just the first 15. |
21286 | New FPGA Pin Mapping tool to compare and update any PCB component with an external Pin File (BC:2100). |
22728 | Fixed regression where Windows Taskbar did not pop up in an auto-hide mode with AD18 in focus (with Classic Windows theme) after the hide / show Altium Designer. |
23562 | Fixed regression where you could not use the Y or N shortcut key to close Confirm message dialogs. |
23849 | Fixed bug where the Script Custom button in toolbar is empty after restarting AD. |
26222 | Fixed regression where connection lines were not built and DRC Un-Routed Net constraint violations were not being reported for Power Plane Connect Style "No Connect" rules. |
Data Management
22608 | Improved Preview aspect when browsing a Footprint Item in the Explorer panel to display 'Item not found'-type message rather than blank view. |
23278 | Added options for SVN working copy formats on Data Management - Version Control Preferences page (BC:8167). |
24116 | Excel format BOM produced from an OutputJob, where the project includes variants that reference varied parameters via a DbLink, are now updated correctly when the "Include Parameters from Database" option is enabled for BOM generation (BC:1318). |
24630 | Improved speed of Repository browsing and Check Out operations. |
20681 | Fixed regression where too many clicks were required to rename files in the Storage Manager panel. |
20684 | Fixed regression where the Storage Manager did not correctly sort filenames alphanumerically. |
20696 | Fixed regression where switching between project documents in the Projects panel while Storage Manager panel was open switched the Storage Manager panel to a random panel (e.g., Outputs, Messages). |
20737 | Fixed bug where Storage Manager panel did not display "Loading" when checking the status of project files. |
20910 | Fixed bug where there was a typo (loose instead of lose) in the confirmation dialog after performing a revert through the Storage Manager panel. |
21947 | Fixed bug in Explorer panel, where parameters with long value entries were being cut-off. They are now displayed correctly. |
22871 | Fixed Regression where multiple SVN credentials request dialogs appear after Sign In. |
22915 | Fixed regression where software would open with error if the VCS Provider - SVN extension had been removed. |
23597 | Fixed regression that caused the Parts Providers Parameter Import Options to not function correctly. |
23629 | Fixed bug where a particular Digi-Key part (754-2121-1-ND) was available through Octopart, but not through the Altium Parts Provider. |
23630 | Fixed bug where Manufacturer Part Number IS25LP016D-JNLE (Digi-Key: 706-1583-ND) was not being recognized, and data not made available through the Altium Parts Provider. |
23931 | Fixed bug with bad/invalid supplier links and not actual supplier data. |
23948 | Fixed regression where sometimes an error dialog would repeat when performing an auto-backup. |
24045 | Fixed regression that caused software crash when updating Collaboration, Compare and Merge panel. |
24556 | Fixed regression where it was not possible to add or checkout projects from SVN when the folder name path depth was more than 260 symbols. |
25425 | Fixed bug in variants where No-Fit components showed on Mechanical layer 16 when using Mechanical layers 17-32 in Footprints. |
21129 | Fixed bug that caused 'Relative Path to Template File' for BOM templates to not work with Project Releaser. |
23543 | Fixed bug where parameters listing could not be scrolled using the mouse wheel, in the Part Search panel, or Add Supplier Links dialog. |
23742 | Fixed ECO failure when updating Parameters from Database for Alternative Part from DbLib (BC:8624). |
24622 | Fixed regression where an error occurred when trying to open general templates immediately after loading software and a schematic document. |
23527 | Fixed bug with Create SVN Design Repository dialog not displaying correctly when custom scaling level set to 250%. |
25394 | Fixed exception error when trying to apply an empty SVN Libraries Working folder in Preferences. |
ActiveBOM
21314 | Added ability to group grid lines by the columns in the ActiveBOM. |
23310 | New column added to the ActiveBOM Properties panel, Supplier Subtotal per Board = Unit Price * Design Quantity. Also Price per Board now reflects the actual unit cost of the design, while the Order Price continues to reflect the MOQ costs (BC 8796). |
23362 | Improved support for line numbering in an ActiveBOM. |
23821 | Added highlighting of differences in the consolidated BOM. |
24467 | Added BOM Set functionality. |
24739 | Added "Create Manual Solution" feature to ActiveBOM solutions. |
24967 | Added ComponentType and Folder parameters to the BOM. |
25626 | ActiveBOM - Improved the Up/Down button behavior in the Select Columns dialog. |
22991 | Fixed issue where ActiveBOM automatic line numbering could create duplicate line numbers. |
23989 | Fixed regression where Core-unManaged components had 'Component revision state is not defined' BOM status violation in the BomDoc. |
24343 | Fixed bug that caused inconsistencies in 'Revision Status' and 'BOM Status' in the BomDoc for managed components. |
24891 | Fixed regression where same supplier with similar SPN for different manufacturers in custom database provider were not displayed twice in the BOM supplier tile. |
25639 | Fixed bug where manual solutions were not available in version 18.0 on the BomDoc file which was created in version 17.1. |
Draftsman
23814 | Added Color property for Designators in the Board Assembly View to enable global changes to the reference designator color (BC:8755). |
21367 | Aligned features with the user-friendly interface of Altium Designer's PCB editor for features and shortcuts such as selection, zoom, arrow keys and others. |
21375 | Performance improvements to Update Board, including multi-threading, updating only used views. |
25265 | Added support for Assembly view to change all components at once in the Component Display Properties. |
25941 | The Detail View in Draftsman now draws correctly when the Drill Table symbols are changed (BC:9287). |
22411 | Fixed zooming issue when using Space Navigator and both PCB and Draftsman documents are affected at the same time. |
23647 | Fixed regression where cutting line control points could not be moved. |
23838 | Fixed regression where it was not possible to set or edit the Alias name in the BOM Properties Panel (BC:8873). |
24621 | Fixed bug where project parameters were not being shown in Draftsman documents, for projects that have defined variants. |
24700 | Fixed bug where a component with 3D bodies that extend beyond its component geometry source could occlude that part of the assembly view. |
24736 | Fixed bug with Draftsman document, where system parameters beginning with '=VersionControl' would disappear when exporting to PDF (BC:8870). |
24839 | Fixed bug in Draftsman document, where it was not possible to set or edit tolerance values in Ordinate Dimensions for some items (BC:8874). |
24845 | Fixed bug where placing any True Geometry views on a Draftsman document would result in the views being empty (no components shown). |
25120 | Fixed regression in Draftsman where the user parameter defined in sheet template was not available after loading into the .PCBDwf file. |
25133 | Fixed error when generating a PDF from a specific Draftsman document. |
25162 | Fixed the opening of a specific Draftsman document. |
25227 | Fixed case sensitivity when using .designator parameter (BC:9078). |
25248 | Fixed bug with the access violation "An item with the same key has already been added" when placing a Layer Stack Legend for particular Rigid-Flex PCB designs (BC:9039). |
25255 | Fixed bug where a PCB document containing a particular STEP model would cause an error during Update board. |
25386 | Fixed issue with the layer ordering in the Layer Stack Legend where incorrect bottom paste position is shown. |
25390 | Fixed regression where Draftsman incorrectly prompted to save document as a template (BC:8675; BC:8898). |
25411 | Draftsman now produces the same variant hatching styles in both document editor and PDF output. |
25532 | Fixed regression where placed Assembly, Drill Drawing and Fabrication View sizes would be set to incorrect values. |
Schematic
24188 | Improved performance when moving a large number of objects in the schematic. |
25440 | Restored ability to select multiple pins in schematic library using the component pin editor. |
22213 | Fixed regression that caused SCHLIB component properties to be reset in the Properties panel. |
24298 | Fixed regression that caused Update from Libraries command to fail if part has an alternate part variant. |
22998 | Fixed bug in the Properties panel (for SCH/PCB) where different types of selection were being used for the same fields. |
24802 | Fixed bug that caused an access violation if an Update from Libraries was performed, and the project was then closed without saving. |
25129 | Fixed crash when placing a Harness object that goes beyond the sheet work area. |
23581 | Improved the presentation of simulation source entries on the Mixed Sim toolbar |
21284 | Added ability to create Differential Pair class in schematic editor (BC:5151). |
18432 | Fixed bug where a "Parameter name must be unique" message appeared when trying to change characters in the Parameter Name to upper/lower case in the Properties panel. |
23549 | Fixed regression where scrollbar was not available to scroll Model File content, when defining a Sim Model. |
24312 | Fixed bug where the port orientation was wrong after using the PCAD SCH importer. |
24745 | Fixed bug that caused xDxDesigner importer to improperly import multi-part symbols. |
21902 | Fixed bug in Schematic where delay in properties loading occurred when first selecting of schematic component (when PCB editor is started). |
22286 | Fixed bug where the 'Maintain Aspect Ratio' option was not working for a placed Picture on a Multi-board Schematic document. |
21993 | Fixed regression where Point to Point Router Options dialog was missing when placing a wire on schematic in Auto Wire mode. |
23160 | Fixed bug where an exception occurred when using the Import from DXF command in a Multi-board Schematic. The command has been removed as the DXF Importer is not implemented yet. |
23510 | Fixed regression where symbol preview wasn't available in the Sim Model - General/Spice Subcircuit dialog, under the Port Map tab. |
23799 | Fixed bug where |
24322 | Fixed regression where footprint models were missing from schematic library report files. |
24827 | Fixed bug where it was not possible to edit component properties when using the same schematic document across multiple opened projects. |
PCB
17906 | Added Height constraint to imported keepouts in IDF Importer (BC:7259). |
22135 | Smart Grid Insert now works properly with the List Panel. |
22341 | Properties Panel - Added support for formulas (for location and text values, regular calculations, action with current value) (BC:8861). |
22837 | Added support for snapping to the center of holes and center of edges in 3D models (BC:548). |
23132 | Improved Confirm dialog text and controls when deleting selected objects, and all of those objects are currently locked. |
24218 | Backdrilling improved, now supports defining a back drill pair between any layer-pair, and now recognizes connections made with polygon, region and fill objects (BC:8372). |
24732 | Updated the PCB 3D view so highlighted 3D models are rendered with suitable transparency and color. |
25388 | The right mouse Edit Layer command in View Configurations Panel now works correctly. |
25113 | Advanced Snapping options have been restored to the PCB Editor (Board Properties). |
25438 | The Pads transparency setting now works correctly and affects all pad objects. |
25592 | Improved performance of SCH > PCB synchronization (Update Schematic > PCB) when Project contains multiple variants. |
15767 | Fixed bug where the extended new primitive selection using the Tab key was not displayed for polygons. |
16436 | Fixed bug where gloss did not respect other objects on the PCB when there was a gloss differential pair with a preferred long gap. |
17632 | Fixed bug where retracing a differential pair with a big width and gap created hard violations. |
17639 | PCB Import - Fixed imported OrCAD pad diameters. |
18924 | Fixed issue where AD would hang during interactive diff pair routing, when the swap to opposite route point shortcut key (9) was pressed (BC:8630). |
18988 | Fixed regression where deleting a Net Class was not in the Undo buffer. |
18994 | Fixed regression where Pad Via Library editor was opening empty when accessing an existing PVLib |
19546 | Fixed bug in Properties panel where the library status for a pad that has been unlinked from its Pad Template wasn't being change to Local. |
21186 | Fixed regression where "Resize Polygon Pour" command was not working properly. |
21574 | Fixed bug in Multi-board Assembly document, where zooming in would be considerably 'jumpy'. |
21577 | Fixed access violation that would occur when manually routing after customizing the PCB:ManualRoute command. |
21705 | Fixed 3D display issue when viewing an Embedded Board Array from Top View in Orthographic projection. |
22191 | DRC no longer reports violations between different copper objects in a custom footprint pad, if that pad is not assigned to a net (BC:1779). |
22373 | Fixed regression where cursor hangs when moving mouse to select first Slice Track point. |
22501 | Fixed bug that caused the Properties panel Snap Point location to use the wrong coordinates. |
22574 | Fixed regression where it was not possible to remove Pad/Via dependency from a PVLib, when using the Unlink button in the Properties panel. |
22635 | Fixed bug where it was not possible to edit/copy/paste the value of a locked location through the Properties panel. |
22902 | Fixed regression where the previews of components in the Update from PCB Libraries dialog and Libraries panel were not behaving as expected. |
22936 | Fixed bug where software would hang when trying to move an accordion, and the Cross Select option was enabled. |
23020 | Fixed bug where the Shift+M shortcut for toggling the Board Insight Lens was being erroneously presented in the Heads Up display. |
23028 | Fixed bug where the PCB Heads Up display was floating over the top of an external application (even if the software was minimized). |
23067 | Fixed bug where X2.exe would stop working if a PCB document was closed while interactively routing. |
23080 | Fixed regression where software would freeze after exporting to IDF on a particular board. |
23424 | Fixed regression in PCB where changing the layer during a paused interactive process - through the Properties panel - would result in next placed objects being placed on the previous layer. |
23479 | Fixed regression where, while interactively routing and changing the track width on-the-fly, there was no alert if the width needed to be clipped back to within the min/max of the associated Width rule. |
23532 | Fixed regression where xSignals with Display Override option enabled, were not being hidden when switching mode of the PCB panel (to Nets, Components, etc). |
23651 | Fixed bug where 3D measurement lines were being drawn away from the actual measured points. |
23677 | Fixed regression where Alignment option was missing for the Layer Stack Table, when viewing properties through the Properties panel. |
23681 | Fixed bug with incorrect importing of component into a Multi-board Assembly document, when component consists of similar extruded bodies. |
23768 | Fixed regression where polygons were sometimes not updating when their Net Color was being changed and the Net Color Override was toggled On or Off . |
23781 | Fixed regression where the generated Gerber layer order between .EXTREP file and the CAMtastic panel were not synchronized. |
23797 | Fixed regression where, after changing shape/size for Top-Middle-Bottom and Full Stack pads and vias on some non-Top layer, the focus in the Properties panel jumps to the Top Layer. |
23805 | Fixed regression where extruded 3D bodies with zero overall height were being displayed in 3D (in DX10). |
23837 | Fixed bug where, after changing the Rotation Step for a PCB document with an Embedded Board Array, there would be an error: 'Object reference not set to an instance of an object'. |
23899 | Fixed bug where 3D Body Opacity could not be set for multiple selected components. |
24068 | Resolved issue where a PCB lib could not be saved if an interactive process was currently being performed. |
24164 | Fixed regression where the display of PCB Library Footprint names were truncated incorrectly (BC:8692). |
24228 | Fixed bug where project parameters were not updated in Special Strings until the string was selected on PcbDoc after changing parameter value. |
24258 | Fixed regression that caused error when generating Gerber files for layers that contain zero-size primitives. |
24365 | Fixed regression where the warning message 'A command is currently active and save cannot be completed' appeared after launching interactive Diff Pair Routing or the Length Tuning command, twice. |
24399 | Fixed bug where Paste Mask Expansion option was missing for Track and Arc primitives. |
24784 | Unconnected mid layer pads are now correctly removed during Gerber and ODB++ output generation (BC:8961). |
25094 | Fixed regression where the Solder Mask is missing from OutJob PCB 3D PDF prints when Entire Board From Below option is enabled. |
25155 | Fixed controls within the Pick and Place "Custom Filter" dialog (BC:9089). |
25220 | Fixed file loading error when PCB document contained dimension objects from previous version. |
25240 | Fixed regression where Gerber Batch import would produce an access violation (BC:9112). |
25309 | Fixed regression with PCB to SCH Cross Selection and selecting multiple objects. |
25389 | PCB Defaults are now saving the Via and Pad template settings. |
25416 | Fixed incorrect component standoff heights when exporting to STEP files and using multiple layer stacks. |
25433 | Fixed crash when running PCB Design Check in CAMtastic. |
25439 | Fixed regression where the Mask option was not being applied correctly in the PCB panel. |
25462 | Fixed regression where Snap points on 3D bodies were not visible (BC:9013). |
25632 | Fixed crash in Draftsman when setting the Layer Stack Table text height to 0. |
25649 | Fixed runtime errors and "unable to save file" errors after changing Via Template using the Properties Panel and closing the PCB Rules and Constraints Editor. |
23539 | Fixed issue where it was not possible to select more than one primitive on a PCBLIB, if a BomDoc was opened in a separate window and the Cross Selection setting was enabled. |
25138 | Fixed regression where it was not possible to delete locked objects if all selected objects were locked. |
17293 | Fixed bug where it was not possible to define via shapes/sizes on each layer during changing the via shielding stack from Simple to Full Stack or Top-Middle-Bottom. |
18454 | Fixed bug where the Size and Shape properties were not available to update when selected pads had a different stack mode. |
21801 | Fixed bug where "Change Units" command did not work for the 'Snap Distance', when the value from presets has been selected. |
22397 | Fixed bug where the Opacity slider disappeared when a group of 3D Models is selected, and did not reappear when selected for editing. |
23317 | Fixed regression where the new track Width wasn't immediately applied but required a cursor move after pausing PCB routing to enter a new width. |
24268 | Fixed regression where some fonts in the Font Family were not listed in the properties panel. |
24276 | Fixed layout of Arc properties in PCB Properties panel (BC:8693). |
24363 | Fixed bug that caused changes to be applied immediately when trying to find net by Net Name. |
24617 | Fixed regression where it was impossible to un-assign testpoints on net using either the Testpoint Manager or PCB List when both Top and Bottom Testpoints were assigned to a pad, and the pad was moved to top/bottom layer. |
25434 | Fixed bug in the Width slider behavior so that it may now be moved to Min, Preferred, Max positions even when the design rules have the same values (BC:8741). |
23626 | Improved layer name visibility in the Properties panel. Short layer names are now right-aligned. |
23750 | Added TrueType Font support to PCB output PDF files so text may be searched (BC:1482). |
23789 | Added ability to do STEP output without free models by adding 'Skip free 3D bodies' option to Export Options dialog (BC:1240). |
22288 | Multi-Board: Improved behaviour of object collision test after a plane-to-plane alignment. Implemented speed improvements. |
25116 | Added option in View Configuration panel for representation of labels with Special String names in PCB (BC:8832). |
24548 | Updated IDF 3.0++ Exporter to include objects with MultiLayer. |
22090 | Fixed regression where adding an Ibis model would result in X2.exe to stop working. |
22216 | Fixed regression that caused Ctrl+Q hotkey to function when focused on Interactive Properties panel (BC: 8841). |
22896 | Fixed regression where the units were not changed in Violation Details when changing units on PCB. |
23039 | Fixed bug where changing the 3D Body Opacity for a component, through the Properties panel, caused polygon rebuilding. |
23061 | New Graphic Engine - Fixed regression to restore the zoom level to the same depth as previously possible so that very fine grids may be displayed. |
25469 | IPC Footprint Wizard now supports step model preview and generation. |
23089 | Expedition importer now detects plane layers that contain routes, these are now imported as signal layers. |
23782 | Fixed bug where summary DRC information in CAMtastic was not presented correctly. |
23818 | Fixed bug where the default rule, rather than the applicable rule, was being displayed in the Properties panel when performing interactive Diff Pair Routing. |
23853 | Fixed bug where a corrupted 3D body would result, if trying to create an extruded 3D body using Line 90/90 Horizontal Start with Arc (Radius: 100mil). |
24474 | Fixed regression where switching the View to Print in the PCB 3D Print Settings for a project created from templates after generation produces a PCB without solder mask and copper in the generated PDF. |
24492 | Fixed bug where analyzing nets for designs containing FromTos took a long period of time. |
24513 | Fixed regression where the Line Constraints dialog could not be accessed via the Tab key when slicing a Polygon Pour. |
18799 | Updated Polygon Pour options layout in Properties panel. |
23507 | Added support for the new UI theme to the IPC Compliant Footprint Wizard. |