Working with the Fabrication and Assembly Testpoint Usage Design Rule on a PCB in Altium Designer
Altium 제품에 접근할 수 있는 레벨에 따라 사용할 수 있는 기능이 달라집니다. 다양한 레벨의 Altium Designer Software Subscription에 포함된 기능과 Altium 365 플랫폼에서 제공하는 애플리케이션을 통해 제공되는 기능을 비교해보세요.
소프트웨어에서 논의된 기능을 찾을 수 없는 경우, Altium 영업팀에 문의하여 자세한 정보를 확인해주세요.
Rule category: Testpoint
Rule classification: Unary
Summary Copy Link Copied
The Fabrication Testpoint Usage and Assembly Testpoint Usage design rules specify which nets require testpoints for bare-board fabrication testing, or in-circuit assembly testing, respectively. The constraints between these two rules are identical.
Constraints Copy Link Copied
Default constraints for the Fabrication and Assembly Testpoint Usage rule.
- Required - each target net must have a testpoint assigned. You can further sub-specify whether only a single testpoint is required for each net, or whether a testpoint is to be inserted at each 'leaf' node in a target net (pad/via locations that terminate a route). In addition, you can specify that a target net can have more testpoints, although these must be manually assigned.
- Prohibited - each target net must not have a testpoint assigned.
- Don't Care - each target net can have a testpoint assigned. It does not matter if a testpoint cannot be assigned to a net.
How Duplicate Rule Contentions are Resolved Copy Link Copied
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.
Rule Application Copy Link Copied
This rule is obeyed by the Testpoint Manager, Autorouter, the Online and Batch DRC, and during output generation.
Notes Copy Link Copied
- Fabrication and Assembly Testpoint reports can be configured and generated along with other fabrication and assembly outputs, as part of an Output Job Configuration file (
*.OutJob
). Use these reports to interrogate the locations of all valid fabrication and assembly testpoints, assigned in the design, respectively. - Use the Testpoint Manager dialog to identify the status of testpoint coverage for each net in a design, both in terms of bare-board fabrication and in-circuit assembly testing.
- A DRC report, obtained from running a Batch DRC, can be used to identify each net that fails this rule.