PCB_Dlg-DrillPairFormDrill-Pair Properties_AD

Now reading version 15.1. For the latest, read: PCB_Dlg-DrillPairForm((Drill-Pair Properties))_AD for version 18.1


The Drill-Pair Properties dialog.

Summary

This dialog allows the designer to configure a drill pair for the active layer stack, in terms of start and stop layers. Drill pairs must be configured when blind, buried, or build-up type vias are to be used, with a drill pair for each layer-pair that a via spans.

Access

The dialog is accessed from the PCB Editor, through the Drill-Pair Manager dialog, in the following ways:

  • Clicking the Add button.
  • Selecting a currently defined drill pair (other than the Top Layer - Bottom Layer drill pair, when the active stack is the default Board Layer Stack, which cannot be edited) and clicking the Drill Pair Properties button.
The Drill-Pair Manager dialog is accessed by clicking the Drill Pairs button in the Layer Stack Manager dialog. The latter is accessed by choosing the Design » Layer Stack Manager command, from the main menus.

Options/Controls

  • Drill-Pair Properties - the following fields collectively define the drill pair:
    • Start Layer - the start layer for the pair. Choose from any of the currently defined signal and plane layers for the board, as configured and enabled in the active layer stackup.
    • Stop Layer - the stop layer for the pair. Choose from any of the currently defined signal and plane layers for the board, as configured and enabled in the active layer stackup.

Tips

  1. Drill pairs must be defined to suit the layer stack-up style. This should be done in consultation with your board manufacturer to ensure that your design matches their fabrication technology.

 