Parameters are used for components (shown), documents and projects to add detail information to the design.

Summary

Parameters are general purpose text strings that are child objects of a parent object, allowing detail information to be added to that parent object. For example, schematic components make extensive use of parameters. They are used to define the Designator and the Comment, as well as the general purpose parameter strings that can be added by the designer to fully define it. General purpose component parameters can be used for a variety of functions, including: component detail, such as Wattage, Voltage, etc.; supplier detail, including the supplier name and part number; library component design detail, such as the revision number of the symbol; and documentation detail, such as a URL that links to a component datasheet.

Parameters can also be defined at the schematic sheet (document) level and also the project level. Document-level parameters are ideal for defining fields such as the document title and number; project-level parameters are ideal for defining fields such as the designer or the project name.

Availability

Parameters are added as a property of the parent object and are not placed independently like a Text String. Parameters can be added to any of the following design objects:

  • Component - add user-defined parameters in the Parameters region of the Component Properties dialog, or the Library Component Properties dialog if they are being added during component definition in the Schematic Library editor. Designator and Comment parameters are always present for a Component object. To access the dialog, in the Schematic Library editor, double-click a component in the Schematic editor or double-click the component name in the Sch Library panel.
  • Pin - on the Parameters tab of the Pin Properties dialog.
  • Port - on the Parameters tab of the Port Properties dialog.
  • Sheet Symbol - on the Parameters tab of the Sheet Symbol dialog.
  • Document - in the Document Options dialog (Design » Document Options). Parameters are listed on the Parameters tab of the dialog; a number of default parameters are automatically included in a new schematic sheet.
  • Project - in the Project Options dialog (Project » Project Options). Parameters are listed on the Parameters tab of the dialog.
While attributes can be modified during placement (Tab to bring up associated properties dialog), bear in mind that these will become the default settings for further placement unless the Permanent option on the Schematic – Default Primitives page of the Preferences dialog is enabled. When this option is enabled, changes made will affect only the object being placed and subsequent objects placed during the same placement session.

Graphical Editing

Visible strings can be edited graphically, using what is known as in-place editing. To edit a string in-place, click once to select, pause for a second, then click a second time to enter edit mode.

 Click once to select the string.

 Pause, then click a second time to enter in-place edit mode.

 In this image, the string has been selected and you are ready to type in a replacement string.

The value of the designator string can be edited in-place.

Once editing is complete, press Enter or click away from the string to exit in-place editing mode.

If attempting to graphically modify an object that has its Locked property enabled, a dialog will appear asking for confirmation to proceed with the edit. If the Protect Locked Objects option is enabled on the Schematic – Graphical Editing page of the Preferences dialog and the Locked option for that design object is enabled as well, then that object cannot be selected or graphically edited. Double-click on the locked object directly and disable the Locked property or disable the Protect Locked Objects option to graphically edit the object.

Via an Inspector Panel

Panel pages: SCH Inspector, SCHLIB InspectorSCH Filter, SCHLIB Filter

An Inspector panel enables the designer to view and edit the properties of one or more design objects in the active document. Used in conjunction with the Find Similar Objects dialog, the panel can be used to make changes to multiple objects of the same kind in one convenient location.

The Inspector panel also supports adding additional parameters to selected components. Click Add User Parameter at the bottom of the panel, enter the parameter Value then press Enter. A dialog will then appear prompting for the Parameter Name.

Via a List Panel

Panel pages: SCH List, SCHLIB List, SCH Filter, SCHLIB Filter

List panel allows the designer to display design objects from one or more documents in tabular format, enabling quick inspection and modification of object attributes. Used in conjunction with appropriate filtering - by using the applicable Filter panel, or the Find Similar Objects dialog - it enables the display of just those objects falling under the scope of the active filter – allowing the designer to target and edit multiple design objects with greater accuracy and efficiency.

Component Parameters

Component parameters include the designator and comment, as well as any user-defined parameters.

Editing Component Parameters in the Schematic Library Editor

By default, the designator, comment, and user-defined parameters are not visible in the Schematic Library editor. They are edited in the Library Component Properties dialog. To open the dialog, double-click on the Component name in the SCH Library panel or click the Edit button.

Double click on the component name or click the Edit button to open the dialog and edit the component parameters in the library editor.

User-defined parameters can be displayed by enabling their Visible checkbox in the Library Component Properties dialog. Enabling this will display the parameter Value. To display the parameter name, click the Edit button to open the Parameter Properties dialog where the Visible checkbox for the Name field can be enabled.

Alternatively, the designator and comment strings can be displayed in the Schematic Library Editor, and then doubled-clicked on to edit their properties. To display these strings, select Tools » Document Options to open the Schematic Library Options dialog, then enable the Always Show Comment/Designator option, as shown in the image below. This setting is a property of the current Schematic Library.

Enable the Always Show Comment/Designator option to display these strings in the Schematic Library Editor.

Editing Component Parameters in the Schematic Editor

Component parameters can be defined in the Schematic Editor as the component is being placed or after the component has been placed on a schematic sheet.

  • To define the designator/comment/user-parameter during component placement, press the Tab key while the component is floating on the cursor. The Properties for Schematic Component dialog will open. Enter the required designator/comment/user-defined parameter string and click OK to close the dialog and complete the component placement. Continue to place components or press Esc to terminate placement.
  • To define the designator/comment/user-parameter after placement, double-click on the placed component to open the Properties for Schematic Component dialog where the designator/comment/user-parameter can be edited. Click OK to close the dialog and commit the change.

Editing the Display Properties of Component Parameters

The appearance of the designator/comment/user-parameter strings, which includes the font type, size and color, can be defined as:

  1. A property of the symbol, by setting the properties of the designator/comment/user-parameter in the Parameter Properties dialog in the Schematic Library Editor. This requires the designator string to be made visible, as described previously.
  2. By editing the component designator/comment/user-parameter string of the placed schematic component - double-click on the component to edit the different parameter properties.

Both approaches open the Parameter Properties dialog, as shown below. Note that all properties of the parameter can be edited in this dialog.

The value and the appearance of the Designator string can be edited in the Parameter Properties dialog.

Fixing the Location of the Parameter Strings

The default behavior of a component parameter string is to autoposition it when a component is rotated during placement. If this behavior is not required, turn off the Autoposition option in the Parameter Properties dialog (refer to the previous image) either during symbol creation or after the component has been placed on a schematic sheet. Note that doing this sets this parameter to be classified as a manual parameter (meaning manually positioned parameter). Manual Parameters are identified by a dot on the lower left corner of their selection box.

Control the display of manual parameter marker dots using the Mark Manual Parameters option on the Schematic - Graphical Editing page of the Preferences dialog.

Special Purpose Component Parameters

Special purpose component parameters have been created for defining links from components to related documentation. These include the HelpURL and the ComponentLink parameter pair.

The HelpURL Parameter

The HelpURL parameter allows you to define a link from a component to an external document, such as a PDF or web page. The link is activated when you press F1 over the component on the schematic sheet, or when that component in selected in the Libraries panel. Using this parameter, you can reference a PDF or text file, or an HTML page. To use the feature, add the HelpURL parameter to the required component and set the value of the parameter to the document you wish to open.

When specifying the value for the parameter, you can either include an absolute path or just enter the document name. The following examples are valid entries for the value of the parameter:

  • C:\Design_Projects\Schematics\Modifications.txt
  • From Idea to Manufacture - Driving a PCB Design through AD.pdf
  • www.altium.com

When F1 is pressed with the cursor hovering over the placed object, a search for the document is conducted as follows:

  • If a path 'to' is specified, this location is searched first.
  • If the document cannot be found at this location, or if no path is specified, the \Help folder of the Altium Designer installation is searched.
  • If the document cannot be found, the default help topic for the object is displayed.
The target document can also be accessed by right-clicking over the placed part in the workspace. The entry for the link will appear as the top entry in the References sub-menu, entitled Help.

The ComponentLink Parameter Pair

This feature enables you to define and present named links to any number of reference documents. Multiple ComponentLink parameter pairs can be defined. To use this feature, add and configure the two parameters for each ComponentLink pair as follows:

First parameter - used to define the target document:

  • Parameter Name = ComponentLinknURL (where n is any integer value)
  • Parameter Value = target document path\name

Second parameter - used to define the entry that appears in the menu:

  • Name = ComponentLinknDescription (where n is the same integer value used in the first parameter)
  • Value = Entry to appear in the menu

Any number of ComponentLink parameter pairs can be defined; each pair is associated by sharing the same value for n.

To access component links, right-click on the placed part in the workspace. The entry for the link will appear in the References sub-menu.

Replacing the Value of a String with a Parameter Value

Component parameters can easily be displayed by using their Visible checkbox. This is not the case for Document or Project parameters, which cannot be directly displayed on the schematic sheet. To display these parameters, a technique known as String Indirection is used. String Indirection is a system where a standard text string is placed on the schematic sheet, and instead of entering a string value, you enter the name of a Document or Project parameter preceded by an equals sign, for example =Title. The software automatically detects such strings and instead of displaying the contents of the text string, such as =Title, it checks the Document and Project parameters and if a parameter called Title is found, the value of the Title parameter is displayed.

Indirected strings are known as Special Strings. There is a large number of predefined special strings, which are listed below. Any user-defined document or project parameter can also be thought of as a special string and be indirected to a Text String on the schematic sheet.

Indirected strings are always interpreted and displayed during output generation, such as printing the schematic sheets. Many are also interpreted and displayed directly on-screen.

Use Special Strings to define fields in a title block. The string indirection feature will ensure the correct information for the active schematic is extracted from the document parameters and displayed in the title block.

Schematic Predefined Special Strings

The following are the predefined special strings available for use on a schematic document. The majority of these link to default parameter information defined for the active document on the Parameters tab of the Document Options dialog (Design » Document Options).

  • =Address1 – displays the value specified for the default document-level parameter Address1.
  • =Address2 – displays the value specified for the default document-level parameter Address2.
  • =Address3 – displays the value specified for the default document-level parameter Address3.
  • =Address4 – displays the value specified for the default document-level parameter Address4.
  • =Application_BuildNumber – displays the version and build for the current Altium Designer installation.
  • =ApprovedBy – displays the value specified for the default document-level parameter ApprovedBy.
  • =Author – displays the value specified for the default document-level parameter Author.
  • =CheckedBy – displays the value specified for the default document-level parameter CheckedBy.
  • =CompanyName – displays the value specified for the default document-level parameter CompanyName.
  • =CurrentDate – the current date, automatically calculated from the user's system settings and in the format dd/mm/yyyy, updated upon editing the schematic or on refresh/redraw. Example: 10/12/2015.
  • =CurrentTime – the current time, automatically calculated from the user's system settings and in the format h:mm:ss AM/PM, updated upon editing the schematic or on refresh/redraw. Example: 2:39:47 PM.
  • =Date – used to display static date information. Displays the value specified for the default document-level parameter Date. Unlike the =CurrentDate special string, which is automatically calculated and presented in a set format, the user can enter static date information in any format they like.
  • =DocumentFullPathAndName – used to display the full path and name of the document into which the string is placed. Example: C:\MyTestDesign\PSU.SchDoc.
  • =DocumentName – used to display the schematic's file name only (without the file path). Example: PSU.SchDoc.
  • =DocumentNumber – displays the value specified for the default document-level parameter DocumentNumber. The source parameter can also be updated through the Sheet Numbering for Project dialog, when using the Tools » Number Schematic Sheets command.
  • =DrawnBy – displays the value specified for the default document-level parameter DrawnBy.
  • =Engineer – displays the value specified for the default document-level parameter Engineer.
  • =ImagePath – displays the value specified for the default document-level parameter ImagePath.
  • =ModifiedDate – the modified date stamp of the schematic, automatically populated. Example: 10/12/2015.
  • =Organization – displays the value specified for the default document-level parameter Organization.
  • =ProjectName – displays the actual name of the project (including extension). For example, for a project with filename MyPCB.PrjPcb, this special string will display MyPCB.PrjPcb.
  • =Revision – displays the value specified for the default document-level parameter Revision.
  • =Rule – displays the value specified for the default document-level parameter Rule. The value for this parameter will initially be Undefined Rule (appearing as * on the schematic). Double-click on the parameter value to access the ability to define a rule type and edit its constraint(s).
  • =SheetNumber – the sheet number of the current schematic. This value is calculated when using the Tools » Number Schematic Sheets command. The assigned sheet number, in the Sheet Numbering for Project dialog, will be entered into the value for the default document-level parameter SheetNumber. The special string when used on the Editor tab view of the schematic sheet will source its information from here.
  • =SheetTotal – the sheet total for the project. This value is calculated when using the Tools » Number Schematic Sheets command. The sheet total, in the Sheet Numbering for Project dialog, will be entered into the value for the default document-level parameter SheetTotal. The special string when used on the Editor tab view of the schematic sheet will source its information from here.
  • =Time – used to display static time information. Displays the value specified for the default document-level parameter Time. Unlike the =CurrentTime special string, which is automatically calculated and presented in a set format, the user can enter static time information in any format.
  • =Title – displays the value specified for the default document-level parameter Title.
  • =VariantName - displays the variant from which output has been generated. This follows the entry for the current variant. If the base design is used to generate the output, the value will simply be [No Variations].
  • =VersionControl_RevNumber – the current revision number of the document. Version control must be used for this string to contain any information.

Remember that the full list of special strings available in the Annotation dialog will also include any derived from user-defined document-level and project-level parameters.

Sheet numbers can be manually defined, or they can be assigned using Tools » Number Schematic Sheets. This command opens the Sheet Numbering for Project dialog, which can be used to assign consecutive numbers to each sheet in the project.

Special Strings for Use with Component Parameters

Several additional special strings (or special interpretations of existing ones) are available when defining component parameters. In each case, the special string is entered as the value for a parameter.

  • =CurrentFootprint – displays the name of the currently assigned footprint for the component as defined in the Models region of the associated Component Properties dialog.
  • =Comment – displays the value appearing in the component's Comment field as defined in the Properties region of the associated Component Properties dialog.
  • =Description – displays the value appearing in the component's Description field as defined in the Properties region of the associated Component Properties dialog.
  • =[ParameterName] – displays the value defined for a specified component parameter. Enter the actual name of a component parameter as the special string name. For example, for a component parameter named PowerRating, enter =PowerRating. When defining the Comment property for a component, the associated drop-down field will be populated with special strings for all existing component parameters enabling quick use of any defined parameter's value for the Comment.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
注記

利用できる機能は、Altium 製品のアクセスレベルによって異なります。Altium Designer ソフトウェア サブスクリプション の様々なレベルに含まれる機能と、Altium 365 プラットフォーム で提供されるアプリケーションを通じて提供される機能を比較してください。

ソフトウェアの機能が見つからない場合は、Altium の営業担当者に連絡して 詳細を確認してください。