PadYSize_AllLayers

Now reading version 2.1. For the latest, read: PadYSize_AllLayers for version 4

This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

Parent page: PCB Query Functions - Fields

Summary

Returns all simple pad objects, whose Y Size (All Layers) property complies with the Query.

Syntax

PadYSize_AllLayers : Number

Number will follow the measurement units currently employed for the document – either Imperial (mil; 1mil = 0.001inch) or Metric (mm; 1mm = 0.001meter).

A specific option for the measurement unit can be specified – overriding the default units specified at the document level – through use of an additional measurement unit-based keyword:

  • AsMils(PadYSize_AllLayers) : Number – to specify a size in mil.
  • AsMM(PadYSize_AllLayers) : Number – to specify a size in mm.

Example Usage

PadYSize_AllLayers = 100
Returns all simple pad objects whose Y Size (All Layers) property is equal to 100 current measurement units.

PadYSize_AllLayers >= 4.064
Returns all simple pad objects whose Y Size (All Layers) property is greater than, or equal to, 4.064 current measurement units.

AsMils(PadYSize_AllLayers) > 80
Returns all simple pad objects whose Y Size (All Layers) property is greater than 80mil.

AsMM(PadYSize_AllLayers) Between 1.524 And 3.81
Returns all simple pad objects whose Y Size (All Layers) property is greater than or equal to 1.524mm and less than or equal to 3.81mm.

PadYSize_AllLayers <> 50
Returns all simple pad objects whose Y Size (All Layers) property is not equal to 50 current measurement units.

Tips

  1. The Y Size (All Layers) property is only defined for pads whose Stack Mode property is set to Simple.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.