Hole

This document is no longer available beyond version 4. Information can now be found here: Hole for version 5

This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

Parent page: PCB Query Functions - Fields

Summary

Returns all pad and via objects whose Hole Size property complies with the Query.

Syntax

Hole : Number

Number will follow the measurement units currently employed for the document – either Imperial (mil; 1mil = 0.001inch) or Metric (mm; 1mm = 0.001meter).

A specific option for the measurement unit can be specified – overriding the default units specified at the document level – through use of an additional measurement unit-based keyword:

  • AsMils(Hole) : Number – to specify a hole size in mil.
  • AsMM(Hole) : Number – to specify a hole size in mm.

Example Usage

Hole = 16
Returns all pad and via objects that have a Hole Size property which is 16 current measurement units.

Hole >= 0.508
Returns all pad and via objects that have a Hole Size property which is greater than or equal to 0.508 current measurement units.

AsMils(Hole) Between 12 And 32
Returns all pad and via objects that have a Hole Size property which is greater than or equal to 12mil and less than or equal to 32mil.

AsMM(Hole) < 1.016
Returns all pad and via objects that have a Hole Size property which is less than 1.016mm.

Tips

  1. The Hole Size property is only defined for pad and via objects.
  2. This function is an alias for the HoleDiameter and HoleSize functions.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.