Bus Entry

Now reading version 19. For the latest, read: Bus Entry for version 21
 

Parent page: Schematic Objects

Bus Entries can be used to connect Wires to a Bus.Bus Entries can be used to connect Wires to a Bus.

Summary

A Bus Entry is an electrical design primitive that is used to connect a Wire to a Bus line. It has the ability to allow two different nets to connect to the same point on a Bus – if this was done using Wires, the two nets would short. If this capability is not required, bus entries do not need to be used.

Availability

Bus entries are available for placement in the Schematic Editor only by:

  • Choosing Place » Bus Entry from the main menus.
  • Clicking the Bus Entry button () in the net wiring objects drop-down on the Active Bar located at the top of the workspace. Click and hold an Active Bar button to access other related commands. Once a command has been used, it will become the topmost item on that section of the Active Bar.
  • Clicking the  button on the Wiring toolbar (click View » Toolbars » Wiring to activate) .
  • Right-clicking then choosing Place » Bus Entry from the context menu.

Placement

After launching the command, the cursor will change to a cross-hair and you will enter Bus Entry placement mode.

  1. Click or press Enter to place a Bus Entry at the cursor position.
  2. Press Spacebar to rotate the Bus Entry counterclockwise (in increments of 90°) or press Shift+Spacebar to rotate clockwise.
  3. Press the X or Y keys while in placement mode to mirror the Bus Entry along the X-axis or Y-axis.
  4. Continue placing bus entries or right-click or press Esc to exit placement mode.

During placement, press the Tab key to pause the process and access the Bus Entry mode of the Properties panel from where its line properties can be changed on-the-fly. Click the workspace pause button overlay ( ) to resume placement.

Attributes modified during placement (via the Properties panel) will become the default settings for further placement unless the Permanent option on the Schematic – Defaults page of the Preferences dialog is enabled. When this option is enabled, changes made will affect only the object being placed and subsequent objects placed during the same placement session.

Graphical Editing

To move a Bus Entry, click and hold on it (the cursor will jump to the nearest electrical hotspot), then move it to the new location – connected Buses and Wires will remain attached. While moving the Bus Entry, use the X and Y keys to change the Bus Entry orientation on those axes.

If attempting to graphically modify an object that has its Locked property enabled, a dialog will appear asking for confirmation to proceed with the edit. If the Protect Locked Objects option is enabled on the Schematic – Graphical Editing page of the Preferences dialog, and the Locked option for that design object is enabled as well, then that object cannot be selected or graphically edited. Click the locked object to select it then disable the Locked property in the List panel or disable the Protect Locked Objects option to graphically edit the object.

Non-Graphical Editing

The following methods of non-graphical editing are available:

Via the Properties Panel

Panel page: Bus Entry Properties

This method of editing uses the associated Properties panel mode to modify the properties of a Bus Entry object.

The Bus Entry mode of the Properties panel.The Bus Entry mode of the Properties panel.

During placement, the Bus Entry mode of the Properties panel can be accessed by pressing the Tab key.

After placement, the Bus Entry mode of the Properties panel can be accessed in one of the following ways:

  • Double-clicking on the placed Bus Entry object.
  • Placing the cursor over the Bus Entry object, right-clicking then choosing Properties from the context menu.
  • If the Properties panel is already active, by selecting the Bus Entry object.
The Bus Entry properties can be accessed prior to entering placement mode from the Schematic – Defaults page of the Preferences dialog. This allows the default line properties for the Bus Entry object to be changed, which will be applied when placing subsequent bus entries.

Editing Multiple objects

The Properties panel supports multiple object editing, where the property settings that are identical in all currently selected objects may be modified. When multiples of the same object type are selected manually, via the Find Similar Objects dialog or through a Filter or List panel, a Properties panel field entry that is not shown as an asterisk (*) may be edited for all selected objects.

Via the SCH List Panel

Panel pages: SCH List, SCH Filter

List panel displays design object types from one or more documents in tabular format, enabling quick inspection and modification of object attributes.

Used in conjunction with appropriate filtering – by selecting object types (using the panel's Include options), or by using the applicable Filter panel or the Find Similar Objects dialog – it enables the display of just those objects falling under the scope of the active filter. The properties for all the listed objects may then be edited directly in the List panel.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Note

The features available depend on your Altium product access level. Compare features included in the various levels of Altium Designer Software Subscription and functionality delivered through applications provided by the Altium 365 platform.

If you don’t see a discussed feature in your software, contact Altium Sales to find out more.

Content