Library Component Rule Check
Created: October 11, 2017 | Updated: October 11, 2017
| Applies to versions: 18.0, 18.1, 19.0, 19.1, 20.0, 20.1 and 20.2
Now reading version 19.0. For the latest, read: Library Component Rule Check for version 22
Summary
The Library Component Rule Check dialog provides controls to run a component rule check in the schematic library editor that generates a text report for specified settings.
Access
From the schematic library editor, click Reports » Component Rule Check from the main menus.
Options/Controls
Duplicate
- Component Names - enable this option to check for duplicated component names.
- Pins - enable this option to check for duplicated pins.
Missing
- Description - enable this option to check for missing descriptions.
- Footprint - enable this option to check for missing footprint names.
- Default Designator - enable this option to check for missing default designators.
- Pin Name - enable this option to check for missing pin names.
- Pin Number - enable this option to check for missing pin numbers.
- Missing Pins In Sequence - enable this option to check for missing pins in a sequence.