Signal Integrity - Flight Time - Falling Edge

Now reading version 17.0. For the latest, read: Signal Integrity - Flight Time - Falling Edge for version 21
 

Rule category: Signal Integrity

Rule classification: Unary

Summary

This rule specifies the maximum allowable flight time on signal falling edge. Flight time is the signal delay time introduced by the interconnect structure. It is calculated as the time it takes for the signal on the net to fall to the threshold voltage (marking the transition from signal HIGH to signal LOW), less the time it would take for a reference load (connected directly to the output) to fall to the threshold voltage.

Constraints

Default constraints for the Flight Time - Falling Edge rule.

  • Maximum (seconds) - the value for the maximum permissible flight time on the falling edge of the signal.

How Duplicate Rule Contentions are Resolved

All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.

Rule Application

Batch DRC and during Signal Integrity analysis.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Note

The features available depend on your Altium product access level. Compare features included in the various levels of Altium Designer Software Subscription and functionality delivered through applications provided by the Altium 365 platform.

If you don’t see a discussed feature in your software, contact Altium Sales to find out more.

Content