Query_Lang-PCBFunctions_Fields_SlotHoleLengthSlotHoleLength_AD

Nexus message

This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

Parent page: PCB Query Functions - Fields

Summary

Returns all pad objects whose Hole Length property complies with the Query.

Syntax

SlotHoleLength : Number

Number will follow the measurement units currently employed for the document – either Imperial (mil; 1mil = 0.001inch) or Metric (mm; 1mm = 0.001meter).

A specific option for the measurement unit can be specified – overriding the default units specified at the document level – through use of an additional measurement unit-based keyword:

  • AsMils(SlotHoleLength) : Number – to specify a length in mil.
  • AsMM(SlotHoleLength) : Number – to specify a length in mm.

Example Usage

SlotHoleLength = 50
Returns all pad objects that have an Hole Length property which is 50 current measurement units.

SlotHoleLength >= 50
Returns all pad objects that have an Hole Length property which is greater than, or equal to, 50 current measurement units.

AsMils(SlotHoleLength) Between 20 And 50
Returns all pad objects that have an Hole Length property which is greater than, or equal to, 0.5mil and less than, or equal to, 0.6mil.

AsMM(SlotHoleLength) < 1.5
Returns all pad objects that have an Hole Length property which is less than 1.5mm.

Tips

  1. The Hole Length property is only defined for pad objects.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.