WorkspaceManager_Err-BusIndicesOutOfRangeBus Indices Out of Range_AD

Parent category: Violations Associated with Buses

Default report mode:

Summary

This violation occurs when the index of a constituent net connected to a bus lies outside the range specified by the net to which the bus is associated.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Bus index out of range on <NetPrefix> Index = <NetIndex>

where:

  • NetPrefix is the prefix of the constituent net connected to the bus (e.g. A for net A8, connected to a bus associated to net A[0..7]).
  • NetIndex is the erroneous index of the constituent net (e.g. net A8 has an index of 8).

Recommendation for Resolution

With the violation selected in the Messages panel, use the Details region of the panel to quickly cross probe to the net label associated with the offending net and either amend the index of the net so that it lies within the correct range, or rename the net altogether. The latter would be typical if you have named the net by mistake and it is not a constituent of the net transported by the bus object.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Note

The features available depend on your Altium product access level. Compare features included in the various levels of Altium Designer Software Subscription and functionality delivered through applications provided by the Altium 365 platform.

If you don’t see a discussed feature in your software, contact Altium Sales to find out more.