Query_Lang-PCBFunctions_Fields_BarCodeFullHeightBarCodeFullHeight_AD

您正在阅读的是 3.2. 版本。关于最新版本,请前往 Query_Lang-PCBFunctions_Fields_BarCodeFullHeight((BarCodeFullHeight))_AD 阅读 4 版本

This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

Parent page: PCB Query Functions - Fields

Summary

Returns all text string objects whose BarCode Full Height property complies with the Query.

Syntax

BarCodeFullHeight : Number

Number will follow the measurement units currently employed for the document – either Imperial (mil; 1mil = 0.001inch) or Metric (mm; 1mm = 0.001meter).

A specific option for the measurement unit can be specified – overriding the default units specified at the document level – through use of an additional measurement unit-based keyword:

  • AsMils(BarCodeFullHeight) : Number – to specify a height in mil.
  • AsMM(BarCodeFullHeight) : Number – to specify a height in mm.

Example Usage

BarCodeFullHeight = 300
Returns all text string objects that have a BarCode Full Height property which is equal to 300 current measurement units.

BarCodeFullHeight >= 5.08
Returns all text string objects that have a BarCode Full Height property which is greater than or equal to 5.08 current measurement units.

AsMils(BarCodeFullHeight) > 400
Returns all text string objects that have a BarCode Full Height property which is greater than 400mil.

AsMM(BarCodeFullHeight) Between 6.35 And 8.89
Returns all text string objects that have a BarCode Full Height property which is greater than or equal to 6.35mm and less than or equal to 8.89mm.

BarCodeFullHeight <> 550
Returns all text string objects that have a BarCode Full Height property which is not equal to 550 current measurement units.

AsMils(BarCodeFullHeight) <= 650
Returns all text string objects that have a BarCode Full Height property which is less than or equal to 650mil.

AsMM(BarCodeFullHeight) < 11.43
Returns all text string objects that have a BarCode Full Height property which is less than 11.43mm.

Tips

  1. The BarCode Full Height property is only defined for text string objects.
  2. Use of this keyword will also return the text string child primitive objects of group design objects (component, coordinate, dimension, drill table, and layer stack table objects), whose BarCode Full Height property complies with the Query. Should you wish to target solely text string objects that have been configured as barcode text, use an additional keyword prefix to target those objects. An example query expression would be IsBarCodeText And (BarCodeFullHeight = 210).

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.