WorkspaceManager_Err-BusRangeSyntaxErrorsBus Range Syntax Errors_AD

您正在阅读的是 15.1. 版本。关于最新版本,请前往 WorkspaceManager_Err-BusRangeSyntaxErrors((Bus Range Syntax Errors))_AD 阅读 21 版本
 

Parent category: Violations Associated with Buses

Default report mode:

Summary

This violation occurs when the syntax of the net to which the bus is associated is specified incorrectly.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Bus range syntax error <NetName> at <Location>

where:

  • NetName is the name of the parent net to which the offending bus object is associated.
  • Location is the X, Y coordinates for the offending bus object's electrical hotspot.

Recommendation for Resolution

With the violation selected in the Messages panel, use the Details region of the panel to quickly cross probe to the offending net identifier (e.g. net label, port, sheet entry, etc) whose bus syntax is defined incorrectly. The correct syntax should appear in one of the following formats:

  • NetName[LowerIndex..UpperIndex]
  • NetName[UpperIndex..LowerIndex]

For example, consider a bus that carries two constituent nets, A0 and A1. The bus syntax in this case should be A[0..1] or A[1..0]. Examples of incorrect syntax would include: A[0.1], A[1-0], A[0,1], A[..1], and A[0..].

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content