Query_Lang-PCBFunctions_MembershipChecks_TouchesRoomTouchesRoom_AD

您正在阅读的是 24. 版本。关于最新版本,请前往 Query_Lang-PCBFunctions_MembershipChecks_TouchesRoom((TouchesRoom))_AD 阅读 21 版本

Parent page: PCB Query Functions - Membership Checks

Summary

Returns objects that either totally or partially reside within the region occupied by any room object (confinement constraint rule) whose Name property complies with the Query.

Syntax

TouchesRoom(RoomName1 : String,RoomName2 : String,...,RoomNamen : String) : Boolean/Boolean_String

As you define the Query expression, a pop-up list of all existing rooms, by name, is presented.

Example Usage

TouchesRoom('Power')
TouchesRoom('Power') = True
TouchesRoom('Power') = 'True'

Returns objects that either totally or partially reside within the region occupied by any Room whose Name property is Power.

TouchesRoom('COUT1','COUT2')
TouchesRoom('COUT1','COUT2') = True
TouchesRoom('COUT1','COUT2') = 'True'

Returns objects that either totally or partially reside within the regions occupied by any Rooms whose Name property is either COUT1 or COUT2.

TouchesRoom('Monitor','Auxilary','Effects')
TouchesRoom('Monitor','Auxilary','Effects') = True
TouchesRoom('Monitor','Auxilary','Effects') = 'True'

Returns objects that either totally or partially reside within the regions occupied by any Rooms whose Name property is Monitor, or Auxilary, or Effects.

Tips

  1. The single quote characters (') at the start and end of each RoomName string are mandatory.
  2. Parent coordinate, dimension, and Net objects are not returned.
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。