Query_Lang-PCBFunctions_Fields_X1X1_AD

您正在阅读的是 20.1. 版本。关于最新版本,请前往 Query_Lang-PCBFunctions_Fields_X1((X1))_AD 阅读 21 版本

Parent page: PCB Query Functions - Fields

Summary

Returns all arc, component, coordinate, design view, drill table, embedded board array, fill, layer stack table, OLE object, original dimension, pad, text string (comment, designator, free), track, and via objects whose X1 property complies with the Query.

Syntax

X1 : Number

Number will follow the measurement units currently employed for the document – either Imperial (mil; 1mil = 0.001inch) or Metric (mm; 1mm = 0.001meter).

A specific option for the measurement unit can be specified – overriding the default units specified at the document level – through use of an additional measurement unit-based keyword:

  • AsMils(X1) : Number – to specify a value in mil.
  • AsMM(X1) : Number – to specify a value in mm.

Example Usage

X1 = 1200
Returns all arc, component, coordinate, design view, drill table, embedded board array, fill, layer stack table, OLE object, original dimension, pad, text string (comment, designator, free), track, and via objects that have a X1 property which is equal to 1200 current measurement units.

X1 >= 38.1
Returns all arc, component, coordinate, design view, drill table, embedded board array, fill, layer stack table, OLE object, original dimension, pad, text string (comment, designator, free), track, and via objects that have a X1 property which is greater than or equal to 38.1 current measurement units.

AsMils(X1) Between 1000 And 1400
Returns all arc, component, coordinate, design view, drill table, embedded board array, fill, layer stack table, OLE object, original dimension, pad, text string (comment, designator, free), track, and via objects that have a X1 property which is greater than or equal to 1000mil and less than or equal to 1400mil.

AsMM(X1) < 20.32
Returns all arc, component, coordinate, design view, drill table, embedded board array, fill, layer stack table, OLE object, original dimension, pad, text string (comment, designator, free), track, and via objects that have a X1 property which is less than 20.32mm.

Tips

  1. The X1 property is only defined for arc, component, coordinate, design view, drill table, embedded board array, fill, layer stack table, OLE object, original dimension, pad, text string (comment, designator, free), track, and via objects.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。