Off-Grid Object – Объект вне сетки

Вы просматриваете версию 17.1. Для самой новой информации, перейдите на страницу Off-Grid Object – Объект вне сетки для версии 21
 

Parent category: Violations Associated with Others

Default report mode:

Summary

This violation occurs when an object is not aligned to the current Snap grid.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Off grid <ObjectIdentifier> at <Location>

where:

  • ObjectIdentifier identifies the specific object that is currently off-grid. The identifier is composed of the object's type and its name/designator (e.g. Pin <PinDesignator>).
  • Location is the X,Y coordinates for the object's electrical hotspot.

Recommendation for Resolution

Ensure that the Snap grid is enabled on the Sheet Options tab of the Document Options dialog (Design » Document Options). The offending object can be moved back onto grid manually, or by using the Edit » Align » Align To Grid command.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Примечание

Набор доступных функций зависит от вашего уровня доступа к продуктам Altium. Ознакомьтесь с функциями, включенными в различные уровни Подписки на ПО Altium, и функциональными возможностями приложений, предоставляемых платформой Altium 365.

Если вы не видите в своем ПО функцию, описанную здесь, свяжитесь с отделом продаж Altium, чтобы узнать больше.

Content