Floating Power Objects – Неподключенные порты питания

Вы просматриваете версию 15.1. Для самой новой информации, перейдите на страницу Floating Power Objects – Неподключенные порты питания для версии 21
 

Parent category: Violations Associated with Nets

Default report mode:

Summary

This violation occurs when a power port object has been detected to be floating - not electrically connected to a component - within the design. For example the power port may have been placed but is not yet wired up to the rest of the circuit.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Floating Power Object <NetName>

where:

  • NetName is the name of the net associated with the floating power port object.

Recommendation for Resolution

Ensure that the offending power port object is connected into the circuit as required. If the power port is redundant, simply delete it from the design.

Tips

  1. This message is related to the standard, single-signal power port objects. A floating bus power port object (available when the schematic is part of an FPGA project) will be flagged in the Messages panel as a Floating Net Label.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Примечание

Набор доступных функций зависит от вашего уровня доступа к продуктам Altium. Ознакомьтесь с функциями, включенными в различные уровни Подписки на ПО Altium, и функциональными возможностями приложений, предоставляемых платформой Altium 365.

Если вы не видите в своем ПО функцию, описанную здесь, свяжитесь с отделом продаж Altium, чтобы узнать больше.