WorkspaceManager_Err-PortNotLinkedToParentSheetSymbolPort Not Linked To Parent Sheet Symbol_AD

現在、バージョン 19.1. をご覧頂いています。最新情報については、バージョン WorkspaceManager_Err-PortNotLinkedToParentSheetSymbol((Port Not Linked To Parent Sheet Symbol))_AD の 21 をご覧ください。
 

Parent category: Violations Associated with Documents

デフォルトのレポートモード:

概要

This violation occurs when a port on a child sheet is not matched with a sheet entry on the parent sheet symbol. All sheet entries in the parent sheet symbol must be synchronized (matched) to corresponding ports on the child sheet.

通知

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed in the Messages panel in the following format:

Port <PortName> not matched to Sheet-Entry at <Location>

ここで

  • PortNameは、子シート上のポートの名称です。
  • Locationは、ポートの電気的ホットスポットのX、Y座標です。

推奨する解決法

この問題はいくつもの理由によって発生します。

  • ポートに対応するシートエントリーが存在しない。
  • ポートに対応するシートエントリーは存在するが、名称が異なる。
  • ポートに対応するシートエントリーは存在するが、I/Oタイプが異なる。

Use the Details region of the Messages panel to cross-probe to the port in question, then Ctrl+double-click on the port to ascend to the parent sheet symbol. Right-click on the sheet symbol and choose Sheet Symbol Actions » Synchronize Sheet Entries and Ports from the menu that appears. This will open the Synchronize Ports To Sheet Entries dialog for that sheet symbol.

Use the dialog to match the port in question to the required sheet entry. If the sheet entry does not exist, you can create it directly from the dialog. If the sheet entry exists but the Name and/or I/O Type differ, you can determine, as part of the match, whether the Name and I/O Type to be used comes from the port or the sheet entry.

Tips

  1. シートエントリー、およびポートは存在するが、名称と/またはI/Oタイプが異なる場合は、シートエントリーがポートに一致していない旨のエラーメッセージが状況に応じて表示されます。シートエントリーとポートを同期することで、いずれのエラーも解消されます。
  2. Object hints will only appear provided the Enable Connectivity Insight option is enabled on the System - Design Insight page of the Preferences dialog. Use the controls associated with the Object Hints entry in the Connectivity Insight Options region of the page to determine the launch style for such hints (Mouse Hover and/or Alt+Double Click). 

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
注記

利用できる機能は、Altium 製品のアクセスレベルによって異なります。Altium Designer ソフトウェア サブスクリプション の様々なレベルに含まれる機能と、Altium 365 プラットフォーム で提供されるアプリケーションを通じて提供される機能を比較してください。

ソフトウェアの機能が見つからない場合は、Altium の営業担当者に連絡して 詳細を確認してください。

Content