WorkspaceManager_Err-MismatchedBusLabelOrderingMismatched Bus Label Ordering_AD

現在、バージョン 16.0. をご覧頂いています。最新情報については、バージョン WorkspaceManager_Err-MismatchedBusLabelOrdering((Mismatched Bus Label Ordering))_AD の 21 をご覧ください。
 

Parent category: Violations Associated with Buses

Default report mode:

Summary

This violation occurs when two net identifiers associated with the same bus slice define bus labels with ordering that is not in the same direction (ascending or descending).

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Mismatched bus ordering on <NetName> Low value first and High value first

where:

  • NetName is the name of the parent net to which the mismatched bus ordering is associated.

Recommendation for Resolution

With the violation selected in the Messages panel, use the Details region of the panel to quickly trace the affected bus slice and identify the net identifiers (port, net label, sheet entry, etc) whose bus ordering is not consistent. Determine the correct ordering and amend the naming for the erroneous object.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
注記

利用できる機能は、Altium 製品のアクセスレベルによって異なります。Altium Designer ソフトウェア サブスクリプション の様々なレベルに含まれる機能と、Altium 365 プラットフォーム で提供されるアプリケーションを通じて提供される機能を比較してください。

ソフトウェアの機能が見つからない場合は、Altium の営業担当者に連絡して 詳細を確認してください。

Content