WorkspaceManager_Dlg-EditName_FormTestpoint Setup_AD

現在、バージョン 22. をご覧頂いています。最新情報については、バージョン WorkspaceManager_Dlg-EditName_Form((Testpoint Setup))_AD の 21 をご覧ください。
 

The two variations of the Testpoint Setup dialog  Fabrication Testpoint Setup dialog   The two variations of the Testpoint Setup dialog

Summary

The Assembly/Fabrication Testpoint Setup dialog is used to configure testpoint reports. The banner of this dialog will change (either Assembly or Fabrication) depending on whether it was accessed to configure options for an Assembly or a Fabrication Testpoint report.

Testpoints are assigned manually or can be detected automatically by running the Testpoint Manager

Access

Testpoint output can be generated in one of two ways:

  • By using an Assembly or Fabrication Test Point Report output generator in an OutputJob Configuration file (*.OutJob). Output is generated when the configured output generator is run.
  • Directly from within the active PCB document using File » Fabrication Outputs » Test Point Report or File » Assembly Outputs » Test Point Report. Output will be generated immediately upon clicking OK in the dialog.
The settings defined in the Testpoint Setup dialog when generating output directly from the PCB are distinct and separate to those defined for the same output type in an Output Job Configuration file. In the former, the settings are stored in the project file; for the latter, they are stored in the Output Job Configuration file.

Options/Controls

Report Formats

  • Text - enable for standard text format in the report.
  • CSV - enable for standard comma separated value format, which can be imported into a spreadsheet application, such as Excel, for further processing.
  • IPC-D-356A - enable for an IPC netlist file which carries blind and buried via information as well as differentiating between through-hole vias and free pads. When imported into a CAM document along with image and drill data, it facilitates the recovery of original net names used in the PCB design, making the PCB easier to understand and manage within the CAM Editor.

Test Point Layers 

These selections allow you to specify a scope for the report:

  • Top layer - check to include valid testpoints assigned on the top of the board.
  • Bottom layer - check to include valid testpoints assigned on the bottom of the board.

Units

  • Imperial - check to output coordinates in inches.
  • Metric - check to output coordinates in millimeters.

Coordinate Positions

  • Reference to absolute origin - select to use the absolute origin as the reference point for testpoint coordinates.
  • Reference to relative origin - select to use the relative origin as the reference point for testpoint coordinates.

IPC-D-356A Options 

This region of the dialog becomes available only when the IPC-D-356A Report Format option is enabled.
  • Adjacency Information - check to include a list of nets that could possibly be shorted then enter the adjacency criteria in the text box.
  • Board Outline - check to permit the description of outlines and other segment type data that are not connected to a specific net then use the drop-down to select the desired data.
  • Conductor Traces - Refer to the IPC-D-356A spec for more detail.
  • Merge Net-Tie Nets - when enabled, if a design contains nets connected by Net-Tie components, these nets will report as distinguished single nets in the netlist.

Generated Files

All generated testpoint files are named first by type (Fabrication or Assembly), then by filename. For example: Fabrication Testpoint Report for BoardFileName. The following file extensions are used, depending on which of the Report Formats is enabled: .txt, .CSV, .IPC (note that this is an ASCII file).

Location of Generated Files

The output path for generated files depends on how the output was generated:

  • From an OutputJob file - the generated files are stored in a folder within the project folder. The naming and folder structure is defined in the Output Container that the Testpoint output is targeting.
  • Directly from the PCB - the output path is specified in the Project Options - Options dialog. By default, the output path is set to a sub-folder under the folder that contains the Project file and has the name: Project Outputs for ProjectName. The output path can be changed as required. If the option to use a separate folder for each output type has been enabled in the Options tab, then the Testpoint files will be written to a further sub-folder named Testpoint Output.

Automatically Opening the Generated Output

When generating Testpoint output, you can specify that the output be opened automatically in a new CAM document. The way in which this is accomplished depends on how you are generating the output:

  • From an OutputJob file - enable the IPC-D-356A Output auto-load option in the Output Job Options dialog (Tools » Output Job Options from the OutputJob Editor).
  • Directly from the PCB - ensure that the Open outputs after compile option is enabled on the Options tab of the Project Options dialog (Project » Project Options).
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
注記

利用できる機能は、Altium 製品のアクセスレベルによって異なります。Altium Designer ソフトウェア サブスクリプション の様々なレベルに含まれる機能と、Altium 365 プラットフォーム で提供されるアプリケーションを通じて提供される機能を比較してください。

ソフトウェアの機能が見つからない場合は、Altium の営業担当者に連絡して 詳細を確認してください。

Content