Working with a Sheet Entry Object on a Schematic Sheet in Altium Designer

現在、バージョン 18.0. をご覧頂いています。最新情報については、バージョン Working with a Sheet Entry Object on a Schematic Sheet in Altium Designer の 21 をご覧ください。
 

Parent page: Schematic Objects

 A placed Sheet Entry A placed Sheet Entry

Summary

A sheet entry is an electrical design primitive that belongs within a sheet symbol. It is placed within a sheet symbol to designate input/output ports for the symbol. The sheet entries correspond to ports placed in the source schematic sub-sheet that the symbol represents.

Availability

Sheet Entries are available for placement in the Schematic Editor only in the following ways:

  • Choose Place » Sheet Entry from the main menus.
  • Click the Sheet Entry button () in the graphic objects drop-down on the Active Bar located at the top of the workspace. (Click and hold an Active Bar button to access other related commands. Once a command has been used, it will become the top-most item on that section of the Active Bar.)
  • Right-click in the workspace then choose Place » Sheet Entry from the context menu.
  • Click the  button on the Wiring toolbar.

Placement

After launching the command, the cursor will change to a cross-hair and you will enter sheet entry placement mode. Placement is made by performing the following sequence of actions:

  1. Move the sheet entry attached to the cursor over a placed sheet symbol on the sheet.
  2. Adjust the position of the sheet entry in relation to an edge of the sheet symbol, then click or press Enter to anchor the sheet entry to the required edge and complete placement.
  3. Continue placing further sheet entries or right-click or press Esc to exit placement mode.
The coloring of the sheet entry will aid in its correct placement. While outside of a sheet symbol, the entry will appear grayed-out and you will be prevented from placing it. When over a sheet symbol, the entry will turn blue indicating it can be placed at that location. Once placed, the entry will revert to its true coloring as defined by its Fill Color property in the Properties panel.
While attributes can be modified during placement (Tab to access the Properties panel), keep in mind that these will become the default settings for further placement unless the Permanent option on the Schematic – Defaults page of the Preferences dialog is enabled. When this option is enabled, changes made will affect only the object being placed and subsequent objects placed during the same placement session.

Graphical Editing

This method of editing allows you to select a placed sheet entry object directly in the workspace and change its location graphically.

Sheet entries can only be adjusted with respect to their shape by changing their I/O Type in the Properties panel. As such, editing handles are not available when the Sheet Entry object is selected.

A selected Sheet EntryA selected Sheet Entry

  • Click and drag to reposition the sheet entry within its parent sheet symbol as required.
  • Hold Ctrl then click and drag the sheet entry to move it from the current sheet symbol to another sheet symbol on the sheet. Once the sheet entry has cleared the boundary of the source sheet symbol, the Ctrl key can be released.
  • Clicking and dragging the sheet entry outside of the sheet symbol boundary will cause the sheet symbol to automatically resize to accommodate the entry's new location.
Multiple sheet entries can be moved simultaneously by selecting all entries to be moved by holding Ctrl and clicking on one entry in the selection, then dragging the entire selection. Once you begin the drag, the Ctrl key can be released.
If the Enable In-Place Editing option is enabled on the Schematic – General page of the Preferences dialog, you can edit the name for the sheet entry directly in the workspace. Select the sheet entry object then click once to invoke the feature. Type the new name as required and then click away from the sheet entry object or press Enter to effect the change. 
If attempting to graphically modify an object that has its Locked property enabled, a dialog will appear asking for confirmation to proceed with the edit. If the Protect Locked Objects option is enabled on the Schematic – Graphical Editing page of the Preferences dialog, and the Locked option for that design object is enabled as well, then that object cannot be selected or graphically edited. Click the locked object to select it then disable the Locked property in the List panel or disable the Protect Locked Objects option to graphically edit the object.

Non-Graphical Editing

The following methods of non-graphical editing are available:

Via the Properties Panel

Properties page: Sheet Entry Properties

This method of editing uses the associated Properties panel mode to modify the properties of a sheet entry object.

The Sheet Entry mode of the Properties panelThe Sheet Entry mode of the Properties panel

During placement, the Sheet Entry mode of the Properties panel can be accessed by pressing the Tab key.

After placement, the Sheet Entry mode of the Properties panel can be accessed in one of the following ways:

  • Double-click on the placed sheet entry.
  • Placing the cursor over the sheet entry then right-click and choose Properties from the context menu.
  • If the Properties panel is already active, select the sheet entry object.
The sheet entry properties can be accessed prior to entering placement mode from the Schematic – Defaults page of the Preferences dialog. This allows the default properties for the sheet entry object to be changed, which will be applied when placing subsequent sheet entries.

Via a List Panel

Panel pages: SCH List, SCH Filter

List panel allows you to display design objects from one or more documents in tabular format, enabling quick inspection and modification of object attributes. Used in conjunction with appropriate filtering - by using the applicable Filter panel, or the Find Similar Objects dialog - it enables the display of just those objects falling under the scope of the active filter – allowing you to target and edit multiple design objects with greater accuracy and efficiency.

Right-click Sheet Entry Actions

Right-click over a placed sheet entry to pop-up a context-sensitive menu, from which the following commands are available (on the Sheet Entry Actions sub-menu) that act on that sheet entry (or all currently selected sheet entries, where applicable):

  • Jump to Port <PortName> - use this command to jump to the sheet entry's corresponding port on the sub-sheet referenced by that entry's parent sheet symbol.
  • Toggle Sheet Entry IO Type - use this command to toggle the I/O Type for the sheet entry. It is also available by clicking Edit » Move » Toggle Sheet Entry IO Type from the main menus.

Example of toggling sheet entry IO TypeExample of toggling sheet entry IO Type

The actual change depends on the current I/O Type as follows:

  • Unspecified remains Unspecified.
  • Output changes to Input.
  • Input changes to Output.
  • Bidirectional remains Bidirectional.
If multiple sheet entries are currently selected, the command will appear as Toggle Selected Sheet Entries IO Type. The command will apply to all selected sheet entries on the current schematic sheet.
  • Swap Sheet Entry Side - use to relocate the sheet entry to the directly opposite side of its parent sheet symbol. The sheet entry's I/O Type is not changed by the swap. It is also available by clicking Edit » Move » Swap Sheet Entry Side from the main menus.

Example of swapping sheet entry side.Example of swapping sheet entry side.

If multiple sheet entries are currently selected, the command will appear as Swap Selected Sheet Entries Side. The command will apply to all selected sheet entries on the current schematic sheet.
  • Place Harness Connector of Type <HarnessConnectorType> - use to quickly place a harness connector (complete with respective defined harness entries) for connection to the sheet entry.
This command is only available for a sheet entry that has a defined Harness Type.
  • Reverse Selected Sheet Entries Order - use to reverse the order that selected sheet entries appear along the side of a parent sheet symbol. The I/O Type of a sheet entry is not changed by the reordering. It is also available by clicking Edit » Move » Reverse Selected Sheet Entries Order from the main menus. After launching the command, the reordering will take place. The reordering is achieved by mirroring the positions of the selected sheet entries - along a particular sheet symbol side - about an imaginary line at the mid-point of the distance between the extents of the two most-outer selected sheet entries.
Ensure that all sheet entries that you want to reorder are selected prior to launching the command. Two or more sheet entries must be selected for a particular side of a sheet symbol in order for the command to have effect. You can simultaneously reorder sheet entries along different sides of the same parent sheet symbol and across different sheet symbols on the active schematic sheet.

Notes

  1. When a Sheet Entry is connected to a Signal Harness, the Sheet Entry becomes a Harness object. By default, the Sheet Entry will change color to match the color of the Signal Harness. Disable the Sheet Entries and Ports use Harness Color option on the Schematic - Graphical Editing page of the Preferences dialog to specify your own color for Sheet Entries or to use the default color.
  2. When a Sheet Entry is connected to a Harness Connector by a Signal Harness, the Harness Type in the Properties panel is automatically populated with the Harness Type of the Harness Connector. When a Sheet Entry is connected to a Port by a Signal Harness and the Port has a Harness Type declared, the Sheet Entry will become a Harness object and change to the color of the Signal Harness. If you move the Sheet Entry away from the Harness Connector and the Harness Type field is not populated, the Sheet Entry will revert back to the default color.
  3. Should you need to negate (include a bar over the top of) a sheet entry name, this can be done by including a backslash character after each character in the name (e.g., E\N\A\B\L\E\).
  4. When instantiating multiple channels from the same sheet symbol, certain signals are repeated and sent individually to each instantiated channel. With respect to a sheet entry, a signal is repeated by using the Repeat keyword in the sheet entry's name (e.g., Repeat(Headphone)). The sheet entry is then wired to a bus, which in turn carries the individual signals to their correspondingly instantiated destinations.
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
注記

利用できる機能は、Altium 製品のアクセスレベルによって異なります。Altium Designer ソフトウェア サブスクリプション の様々なレベルに含まれる機能と、Altium 365 プラットフォーム で提供されるアプリケーションを通じて提供される機能を比較してください。

ソフトウェアの機能が見つからない場合は、Altium の営業担当者に連絡して 詳細を確認してください。

Content