Monitoring the Health of Your PCB in Altium Designer

現在、バージョン 20.2. をご覧頂いています。最新情報については、バージョン Monitoring the Health of Your PCB in Altium Designer の 25 をご覧ください。
 

Parent page: Laying out Your PCB

The final goal of each PCB design is to get a correct and reliable set of assembly and fabrication outputs, and the purpose of any design tool is to provide a user with tools to find and resolve the issues that could arise during the design process before the design goes to production. During its constant development, Altium Designer delivers enhancements and bug fixes in each release to provide you with a better design experience and to help you avoid some “unhealthy” layout aspects of your PCBs. In some cases, such areas of a board might be fine from the perspective of Altium Designer’s DRC system, not leading to serious fabrication issues. However, they could result in software performance degradation and issues during MCAD co-design or generation of PCB outputs. For example, PCB components could have 360 degrees rotation value in previous versions of Altium Designer, but this situation is not allowed anymore in the current versions – the software will set such components to 0 degrees.

These “unhealthy” board layout elements may be present in designs created in versions of the software before it was improved and fixed in certain areas. To help you to detect and resolve such issues, and other issues that can arise under certain conditions, the PCB Health Checks functionality is available. These checks allow you to discover common issues in the PCB design, fix them, and avoid potential problems during the next stages of the design and manufacturing process.

The Health Check Monitor functionality can be configured using the PCB.HealthCheckMonitor option in the Advanced Settings dialog. Use the following settings to configure the desired feature mode as shown below. The default value is 1.
0 - switched off
1 - user mode
2 - debug mode (makes available additional checks that are under active development).

The Board mode of the Properties panel (available when no object is selected in the active PCB document) includes the Health Check tab that enables you to configure, perform, and explore the results of the PCB Health Check.

The interface to the Health Check Monitor is the Health Check tab of the Properties panel in its Board mode.
The interface to the Health Check Monitor is the Health Check tab of the Properties panel in its Board mode.

Setting Up and Running a Health Check

Available checks are listed in the grid area of the Checks region on the Health Checks tab. All checks are grouped by relevant categories (Regions, Polygons, Components, etc.). Using the checkbox column, you can enable/disable specific checks, or you can use the checkbox in the column header to enable/disable all checks.

A health check is performed automatically when the PCB document is opened. Anytime during the design process, you can run a specific check manually by right-clicking it in the list and selecting the Run Check command or run all enabled checks by clicking the Check All button at the bottom of the list.

Run a specific check or run all checks at once.
Run a specific check or run all checks at once.

If the PCB design document is changed, a warning that the results of the health check are outdated will be shown. Use the Check All button in the warning banner to run the PCB health check and refresh the results.

If there are issues detected for a check, the number of the issues detected for this check will be shown in the Issues column. The total number of issues found for the current PCB design is shown in parentheses in the column header. Also, an icon will be shown in this column. The icon reflects the severity level of the found issue, depending on its type:

  • – Info
  • – Warning
  • – Error

The icon of the most severe issue detected will also be shown next to the Health Check tab title. If there are no issues, the  icon will be shown in the tab title.

Select a check entry to show the list of issues detected for this check in the Issues region of the panel.

Select a check to show the list of detected issues.
Select a check to show the list of detected issues.

To show in the list only checks for which issues are detected, use the Show issues only control at the top of the list.

Use the Show issues only control to filter the checklist.
Use the Show issues only control to filter the checklist.

When the Show issues only control is enabled, you can sort the list of checks by their severity level by clicking the icon column header.

Resolving the Detected Issues

When clicking a check in the Check region of the panel, the panel's Issues region will be populated with the issues detected for this check. Click an issue in the list to zoom, center, and highlight (where possible) an offending object in the PCB editor's design space. Recommendations on how an issue for the selected check can be fixed are shown in the info region of the panel.

The following checks can be fixed automatically:

  • Zero Area Regions
  • Zero Area Polygons
  • Micro-Segments
  • Shelved/Modified Polygons
  • 360deg Component
  • Duplicate Component Designators
  • Unused xSignals
  • Unused From-Tos

To use the automatic fix, select a check in the list and click the Fix Issues button at the bottom of the issue list. Alternatively, right-click a check in the Checks list and select the Fix Issues command from the menu that appears.

Fix the detected issues automatically using the Fix Issues command.
Fix the detected issues automatically using the Fix Issues command.

Performing a Health Check during Output Generation

When trying to generate the outputs from an OutJob file or directly from the PCB editor and the design contains a critical issue (a shelved polygon or a polygon that has been modified but not repoured and/or a panel that has a layer stack non-compatible with the layer stack of the parent board), a warning dialog will be displayed. The dialog shows you a warning that outputs to be generated will not be correct and the number(s) of offending objects. You can cancel output generation and open the Health Check tab right from the dialog or proceed with output generation. For the non-compatible layer stack issue, you will also be able to open the compatibility HTML report.

The PCB Health Check Issues Detected dialog.
The PCB Health Check Issues Detected dialog.

Reporting the Detected Issues

Issues detected by the PCB Health Check Monitor can be listed in the HTML report generated when performing a Batch DRC. In the Design Rule Checker dialog, select the Create Report File option and its Report PCB Health Issues sub-option. After running the Batch DRC using the dialog's Run Design Rule Check button, the number of detected PCB Health Issues will be shown at the top of the report, and the issues will be listed under the PCB Health Issues heading.

The Report PCB Health Issues option in the Design Rule Checker dialog. Hover the cursor over the image to see an example of the generated report when this option is enabled.
The Report PCB Health Issues option in the Design Rule Checker dialog. Hover the cursor over the image to see an example of the generated report when this option is enabled.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
注記

利用できる機能は、Altium 製品のアクセスレベルによって異なります。Altium Designer ソフトウェア サブスクリプション の様々なレベルに含まれる機能と、Altium 365 プラットフォーム で提供されるアプリケーションを通じて提供される機能を比較してください。

ソフトウェアの機能が見つからない場合は、Altium の営業担当者に連絡して 詳細を確認してください。

Content