Controlled Depth Drilling (Back Drilling)

Now reading version 18.1. For the latest, read: Controlled Depth Drilling (Back Drilling) for version 25

 

Controlled Depth Drilling (CDD), also known as back drilling, is a technique used to remove the unused portion, or stub, of copper barrel from a thru-hole in a printed circuit board. When a high-speed signal travels between PCB layers through a copper barrel, it can be distorted. If the signal layer usage results in a stub being present, and the stub is long, then that distortion can become significant.

These stubs can be removed by re-drilling those holes after the fabrication is complete, with a slightly larger drill. The holes are back drilled to a controlled depth, close to, but not touching, the last layer used by the via. Allowing for fabrication and material variations, a good fabricator can back drill holes to leave a 7mil stub, ideally the remaining stub will be less than 10mil.


The via is used to connect between the 2 internal layers, resulting in un-used barrel (stubs) above and below.
These stubs can be removed using controlled depth drilling.

In printed circuit board design, a via stub is a length of copper barrel that projects beyond the the signal layers used to route that signal. This unused portion of copper barrel acts as a stub, creating reflections if the signal switches at high speeds. These stubs can be removed by performing a second drill pass, where the barrel is drilled out to an exact depth, as shown in the adjacent image.

To remove the stubs, the via on the left is back drilled from the top side, the via on the right is back drilled from both sides. Note that both vias have some remaining stub.

Most commonly used for vias, and also for press-fit backplane connectors, back drilling provides a cost-effective solution to help manage the signal quality for high-speed signal paths. It offers lower cost than the sequential lamination technique used for blind and buried vias.

Back drilling is achieved by:

  • Defining a Maximum Via Stub Length (Back drilling) design rule which defines the nets of interest, and also the maximum allowable stub length. Note that this stub length is not a drill setting, it is the value the software uses to check for remaining stubs during a batch DRC.
  • The depth that the hole is back drilled to is defined by configuring a drill pair, that specifies the start and stop layers for back drills from that side of the board.
  • The diameter of the drill used for back drilling is defined by Via/Pad hole size + 2 x Oversize setting in the applicable Maximum Via Stub Length (Back drilling) design rule.

If a via or pad is not used on a signal layer, that unused ring of copper is often referred to as a Non Functioning Pad (NFP). Non Functioning Pads that are on a layer that is to be back drilled, are automatically removed at each back drill hole site. Remaining NFPs can be removed from any design by running the Tools » Remove Unused Pad Shapes command.

Clearance values for polygons and power planes are calculated from the back drill diameter, insuring that a back drill does not drill the copper of a surrounding polygon or power plane.

Targeting the Holes to be Back Drilled

You instruct the software that there are holes to be back drilled by adding a Maximum Via Stub Length (Back drilling) design rule. The scope of the design rule defines which vias or pads are to be drilled. Typically you only back drill selective nets, such as the high-speed nets, in which case the scope could be something like InNet('Clock'), or InNetClass('HighSpeedNets').

The scope of the rule defines which objects this rule must be applied to, this rule targets vias in the IO net class.
The scope of the rule defines which objects this rule must be applied to, this rule targets vias in the IO net class.

For example, if the scope is InNetClass('IO'), then all vias and pads in those nets can potentially be back drilled. The holes that are actually back drilled will depend on which layers those signals are routed on, and which back drill pairs have been defined - if a hole has no connections on the layers within the back drill layer range, then that hole will be back drilled.

To further limit the back drilling operation, tighten the rule scope. For example, if you only want to back drill the vias and not the thru-hole pads, then you could change the rule scope to InNetClass('IO') and IsVia.

To scope a design rule to control the solder mask opening at a back drill hole site, you can use the query keywords shown below.

  • BackDrillTop - apply to vias/pads that have a top side back drill
  • BackDrillBottom - apply to vias/pads that have a bottom side back drill

Defining the Back Drill Properties

When you back drill a thru-hole barrel, an oversized drill bit is used to remove the unwanted copper.

By re-drilling the hole with an oversized drill bit down to a specific depth, the unused portion of the via barrel is removed, improving the integrity of this signal path.     
By re-drilling the hole with an oversized drill bit down to a specific depth, the unused portion of the via barrel is removed, improving the integrity of this signal path.

All layer-to-layer drill actions are defined by adding a start layer-stop layer drill definition in the Drill-Pair Manager.

For a layer pair that you want back drilled, you also enable the Back drill pair checkbox in the Drill-Pair Properties dialog for that layer pair. This instructs the software that holes between the specified layers are candidates to be drilled a second time, oversized by the amount specified in the applicable Maximum Via Stub Length (Back drilling) design rule.

Drill Depth

The back drilling depth is a calculated value, not a number you enter into a dialog. You define the start and stop layers, the software calculates the drill depth required to back drill through all layers between the start and stop layers, including the start layer thickness, but not the stop layer thickness (back drilling stops at that layer). The start-stop layers are defined by adding a drill definition in the Drill-Pair Manager dialog.

The hole is drilled up to, but not touching, the stop layer specified in the drill pair. The depth of the drill action is defined by:

Depth = Sum of all layer thicknesses from start layer to stop layer - stop layer thickness

The layer thicknesses are the values entered into the Layer Stack Manager. The back drill start-stop layers are defined by adding a Back drill pair in the Drill-Pair Manager, click the Drill Pairs button in the Layer Stack Manager to open it. The image below shows the layer thickness values used to calculate the back drill depth of a top side back drill, and a bottom side back drill.

The drill pair(s) are defined in the Drill-Pair Manager, and the depth is calculated from the layer thicknesses.
The drill pair(s) are defined in the Drill-Pair Manager, and the depth is calculated from the layer thicknesses.

From a signal integrity perspective, it is suggested to limit residual stub lengths to 10 mils maximum. From a fabrication perspective, a stub length of less than 7 mills incurs an additional manufacturing cost.

Drill Size

The drill diameter calculated from:

Back Drill Size = Via/Pad hole size + 2 x Design Rule Backdrill Oversize

Rather than entering a specific drill size for back drilling, you define how much larger the back drill is over the original via or pad hole size. The oversize is specified as a radial amount in the design rule, along with any tolerance requirements for the back drilled holes, as shown below.

The size of the drill used for back drilling is the original via or pad hole size, plus twice the Backdrill Oversize specified in the design rule. Note that the Oversize is specified as a radial amount.
The size of the drill used for back drilling is the original via or pad hole size, plus twice the Backdrill Oversize specified in the design rule. Note that the Oversize is specified as a radial amount.

Onscreen Display of Back Drilled holes

The display of holes that are back drilled includes an additional, two-color ring, with the following properties:

  • The inner circle is the original via (brown) or pad (green/blue) hole size.
  • The two-color ring denotes the start layer color and the stop layer color of the back drill.
  • The width of the colored arc is the BackDrill OverSize amount defined in the design rule. The outer diameter of the circle defined by the 2 colored arcs is the actual back drill hole size, which will be listed as a drill size in the Hole Size Editor mode of the PCB panel. 
  • The display of the colored ring is dependent on which layer is currently active in the PCB editor. For example, the first image below is with the top layer active and the second image is with the bottom layer active. If the active layer is not back drilled, (for example if the active layer was Mid Layer 2 or Mid layer 3 in the via shown below), then the back drill would not be displayed at all, you would simply see the via hole in brown surrounded by the multi-layer land area.

The same via, shown on the left with the top layer active, in the center image with the bottom layer active, and in 3D mode.  
The same via, shown on the left with the top layer active, in the center image with the bottom layer active, and in 3D mode.

Checking Back Drilling in the Hole Size Editor

Back drills can also be located and viewed via the Hole Size Editor, set the mode in the PCB panel.

In the image below, the 18mil sized back drill has been clicked on in the panel. The display zooms to those back drilled holes, highlighting them with the start and stop layers. Note that there are 7 back drilled vias shown in the panel, but only 5 are shown in the workspace. That is because the second and third vias are back drilled from both the top side and the bottom side, and since the top layer is the active layer, those vias are currently shown as a top side back drill.

Checking for Stubs

The Maximum Via Stub Length (Back drilling) design rule is used for both locating potential back drill sites, and also for testing for remaining stubs.

During a design rule check, all applicable vias and pads are tested for stubs of a length greater than the Max Stub Length configured in the design rule. Note that all pads and vias targeted by Maximum Via Stub Length (Back drilling) design rules are tested, not just those that are back drilled or those that have not been back drilled.

The rule is checking the length of any remaining stub. In the image below, even though the via has been back drilled, the remaining stub is greater than the 7mil allowed by the applicable design rule, so a rule violation is flagged.


A design rule check flags any stub that is greater than the Max Stub Length allowed by the design rule.
This via fails, as the remaining stub is greater than 7mil.

Violations can be displayed in two ways, using either:

  • Violation Detail - where information is displayed about the type of violation, and when possible, the failure value (as shown in the image above).
  • Violation Overlay - the object in violation is painted with a repeating colored pattern (the default is a cross within a green dot).

The Chosen DRC Violations Display Style is configured in the PCB Editor - DRC Violations Display page of the Preferences dialog.

Generating the Outputs

Generating output for back drilling is transparent, if additional drill-type output files are needed, these are automatically generated.

Back drilling is very similar to using blind vias - these also require a start-stop layer pair to be defined in the Layer Stack Manager, which specifies the drilling requirements between this pair. The difference is that blind vias are plated, whereas back drilled vias or pads are an unplated drill event. Unplated holes are essentially a post-fabrication process, the drilling occurs after the etching, lamination, drilling, and through hole plating. 

Back Drill Report

To generate a summary report of all back drill events in the design, right-click in the Unique Holes region of the Hole Size Editor and select Backdrill Report from the context menu.

Generate a report of all of the Back drill events in the current PCB.
Generate a report of all of the Back drill events in the current PCB.

The Report Preview dialog will open, click the Export button to select the file type, the location the file is to be written to, and to enter the file name. The Save as type options include XLS and PDF.

Drill Symbols, the Drill Table and the Drill Drawing

Drill symbols are automatically assigned, and can be reconfigured in the Drill Symbols dialog. The symbols are displayed on the Drill Drawing layer in the PCB workspace, if the Show Drill Symbols option is enabled in the Drill Symbols dialog. The dialog can be accessed by right-clicking in the Unique Holes region of the panel, or on the Drill Drawing layer tab, as shown below.

Configure the drill symbol assignments and enable their display in the Drill Symbols dialog.
Configure the drill symbol assignments and enable their display in the Drill Symbols dialog.

Because back drilling involves drilling at the same location with different sized drill bits, drill symbols will appear stacked at these locations. Use the layer-pair selector to control which layer pair is currently being displayed, as shown in the images below.

Left-click the triangle icon to select which drill pair you want displayed.   
Left-click the triangle icon to select which drill pair you want displayed.

A placed drill table can be configured to show all drill layer pairs, or it can be configured to show a specific layer pair. The image below is from a design with back drilling from both the top and bottom sides of the board, so three tables have been placed. Note the Drill Layer Pair column, it indicates the function of each table.

Three drill tables have been placed, the first showing the thruhholes, the second the back drills from the top side, and the third showing the back drills from the bottom side.
Three drill tables have been placed, the first showing the thruhholes, the second the back drills from the top side, and the third showing the back drills from the bottom side. 

NC Drill

For each drill pair defined in the Drill-Pair Manager dialog, NC drill output will produce a unique drill file, which can be either text or binary (enable the options as required). Note that is also produces a separate file for each hole-shape type (round, rectangular or slotted).

The drill report file (<ProjectName>.DRR) includes a summary of the: drill tool assignments; their sizes; and the role and name of each of the various drill files generated.

The NC Drill Setup dialog includes the option Generate separate NC Drill files for plated & non-plated holes. The NC drill output files always includes all drill events, if this option is enabled the plated and the non-plated drill events are instead output into separate files. They are identified by an additional string in their filename, in the format <DesignName>-Plated, or <DesignName>-NonPlated.

Back drill events are always output into their own files, each identified by a unique file extension. For example, these could be named <DesignName>-BackDrill.TX3 for the top-side back drill events and <DesignName>-BackDrill.TX4 for the bottom-side back drill events.

The drill report summarizes the assignment of drills to tools, the number of each size, and the drill files they are detailed in.
The drill report summarizes the assignment of drills to tools, the number of each size, and the drill files they are detailed in.

Gerber X2

Rather than a just being a standard for outputting fabrication data for a set of PCB layers (which requires the addition of NC drill files for bare-board fabrication), Gerber X2 outputs all of the data needed to input the design into the fabricator's CAM process. Gerber X2 is configured in the Gerber X2 Setup dialog.

This includes:

  • Gerber file function: top copper layer, top solder mask, etc.
  • Part: single PCB, panel etc.
  • Object function: SMD pad, via pad etc
  • Drill tolerances
  • Locations of impedance-controlled tracks
  • Filled vias

If there are back drilled holes in the design, the X2 output will automatically include additional drill files, with a filename like:

<DesignName>_Backdrills_Drill_1_3.gbr

These back drill files includes Gerber X2 format instructions, such as:

%TF.FileFunction,NonPlated,1,3,Blind,Drill*%

This line instructs the CAM software to treat the contents of this file as non-plated blind drill events, between signal layers 1 and 3.

Drill sizes are defined using apertures, whose definition is preceeded by an instruction that declares them as drill-sizes.

%TA.AperFunction,BackDrill*%

ODB++

For ODB++ output, there will be an additional drill folder created for each back drill layer pair defined. These will have names such as \drill1, \drill2. These folders include the standard ODB drill files.

IPC-2581

Support for IPC-2581 will be added in a future update.

Draftsman

Draftsman is an ideal tool for creating high-quality documentation for your design. If there are back drill type layer-pairs defined in the design, the Layer Stack Legend will display these, making it easy to quickly establish their presence.

Place a Layer Stack Legend to display the layer pairs used for back drilling, and drill tables for each layer-pair drill sets.
Place a Layer Stack Legend to display the layer pairs used for back drilling, and drill tables for each layer-pair drill sets.

You can also configure the drill table to show each back drill layer-pair, making it easy to quickly identify the drill sizes and hole count required for back drilling. 

 

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Note

The features available depend on your Altium product access level. Compare features included in the various levels of Altium Designer Software Subscription and functionality delivered through applications provided by the Altium 365 platform.

If you don’t see a discussed feature in your software, contact Altium Sales to find out more.