WorkspaceManager_Err-SheetEntryNotLinkedToChildSheetSheet Entry Not Linked To Child Sheet_AD
This document is no longer available beyond version 21. Information can now be found here: Sheet Entry not linked to child sheet for version 25
Parent category: Violations Associated with Documents
Default report mode:
Summary
This violation occurs when a sheet entry is not matched with a port on the child sheet referenced by the parent sheet symbol. All sheet entries in the parent sheet symbol must be synchronized (matched) to corresponding ports on the child sheet.
Notification
If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed in the Messages panel in the following format:
Sheet-Entry <SheetEntryName> not matched to Port at <Location>
where:
- SheetEntryName is the name of the sheet entry associated with the parent sheet symbol.
- Location is the X,Y coordinates for the sheet entry's electrical hotspot.
Recommendation for Resolution
This issue can arise for a number of reasons:
- The corresponding port for the sheet entry does not exist.
- The corresponding port for the sheet entry exists but with a different name.
- The corresponding port for the sheet entry exists but with a different I/O Type.
Use the Details region of the Messages panel to cross-probe to the sheet entry in question. Right-click on the parent sheet symbol then choose Sheet Symbol Actions » Synchronize Sheet Entries and Ports from the menu that appears. This will give you access to the Synchronize Ports To Sheet Entries dialog for that sheet symbol.
Use the dialog to match the sheet entry in question to the required port. If the port does not exist, you can create it directly from the dialog. Where the port exists but the Name and/or I/O Type differ, you can determine, as part of the match, whether the Name and I/O Type to be used comes from the sheet entry or the port.
Tips
- When the sheet entry and port exist but have different Names and/or I/O Types, there will be a corresponding error message stating that the port is not matched to a sheet entry. Synchronizing the sheet entry with the port will clear both errors.
- Object hints will only appear provided the Enable Connectivity Insight option is enabled on the System - Design Insight page of the Preferences dialog. Use the controls associated with the Object Hints entry in the Connectivity Insight Options region of the page to determine the launch style for such hints (Mouse Hover and/or Alt+Double Click).