Sch_Dlg-ChangeJunctionJunction_AD

您正在阅读的是 16.0. 版本。关于最新版本,请前往 Sch_Dlg-ChangeJunction((Junction))_AD 阅读 17.1 版本

The Junction dialog.

Summary

This dialog allows the designer to specify the properties of a Manual Junction object. A junction is an electrical design primitive. It is a small circular object used to logically join intersecting wires or buses on a schematic sheet. A manual junction allows you to create a connection between crossed wires or buses, by placing the junction at the crossing point. This is different from a Compiler generated junction, which is automatically inserted when two wires/buses are connected in a T-type fashion, or when a wire/bus connects orthogonally to a pin or power port/bus power port.

For information on how a placed manual junction object can be modified graphically, directly in the workspace, see Graphical Editing.

Access

The Junction dialog can be accessed prior to entering placement mode, from the Schematic – Default Primitives page of the Preferences dialog. This allows the default properties for the manual junction object to be changed, which will be applied when placing subsequent manual junctions.

During placement, the dialog can be accessed by pressing the Tab key.

While attributes can be modified during placement, bear in mind that these will become the default settings for further placement unless the Permanent option on the Schematic – Default Primitives page of the Preferences dialog is enabled. When this option is enabled, changes made will affect only the object being placed and subsequent objects placed during the same placement session.

After placement, the dialog can be accessed in one of the following ways:

  • Double-clicking on the placed manual junction object.
  • Placing the cursor over the manual junction object, right-clicking and choosing Properties from the context menu.
  • Using the Edit » Change command and clicking once over the placed manual junction object.

Options/Controls

  • Color - click the color sample to change the color of the junction, using the standard Choose Color dialog.
  • Location X/Y - the current X (horizontal) and Y (vertical) coordinates for the center point of the junction. Edit these values to change the position of the junction in the horizontal and/or vertical planes respectively.

Properties

  • Size - the size of the junction. Available sizes are: Smallest, Small, Medium, and Large.
  • Locked - enable this option to protect the junction from being edited graphically.
If attempting to graphically modify an object that has its Locked property enabled, a dialog will appear asking for confirmation to proceed with the edit. If the Protect Locked Objects option is enabled on the Schematic – Graphical Editing page of the Preferences dialog, and the Locked option for that design object is enabled as well, then that object cannot be selected or graphically edited. Double click on the locked object directly and disable the Locked property, or disable the Protect Locked Objects option, to graphically edit the object.

Tips

  1. Display of the connection status of manual junctions can be controlled from the Schematic - Compiler page of the Preferences dialog. If the Display option is enabled each manual junction that is creating a valid connection is back-colored, in the color defined by the Color option. Note that the default Size of the Connection Status display feature is Smallest, which is the same size as the default manual junction size. This means the back-color will not be visible, unless the Size is set to Small or larger.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。