Query_Lang-PCBFunctions_Fields_FromToPad2FromToPad2_AD

This document is no longer available beyond version 21. Information can now be found here: FromToPad2 for version 25

Parent page: PCB Query Functions - Fields

Summary

Returns all from-to objects whose To Pad property complies with the Query.

While from-to objects will be returned in the PCB List panel, in order to see these in the workspace, you will need to apply the filter query after placing the PCB panel into From-To Editor mode.

Syntax

FromToPad2 : PadName_String

PadName_String specifies the full Name that a pad has to match; this consists of an initial substring which specifies the Name property of the pad's parent component (i.e. the component's Designator), followed by a substring that specifies the pad's own Name property (i.e. the pad's Designator). The format will therefore be 'ParentComponentDesignator-PadDesignator'.

Example Usage

FromToPad2 = 'U1-8'
Returns all from-to objects whose To Pad property is U1-8.

Tips

  1. The single quote characters (') at the start and end of PadName_String are mandatory.
  2. The To Pad property is only defined for from-to objects.
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.