Working with the Max Via Stub Length (Back Drilling) Design Rule on a PCB in Altium Designer

您正在阅读的是 16.0. 版本。关于最新版本,请前往 Working with the Max Via Stub Length (Back Drilling) Design Rule on a PCB in Altium Designer 阅读 21 版本
 

Rule Category: High Speed

Rule Classification: Unary

Summary

A stub is the length of via or pad barrel that protrudes beyond the last-used signal layer that the via/pad connects on. Back drilling will be applied to suitable vias/pads in nets targeted by this rule, in accordance with the enabled side-of-board Layer checkboxes, and the back drill [BD] pairs defined in the Drill-Pair Manager.

As well as being used to define which vias/pads are to be considered for back drilling, during design rule checking this rule tests for via and pad stubs longer than the specified Max Stub Length, for all nets targeted by this rule (regardless of whether back drilling has been applied to that via or pad). This rule also specifies how much larger the drill size must be for vias and pads that are back drilled.

Use appropriate rule scoping to target vias/pads in a specific net (or collection of nets), using query expression keywords such as InNet, InNetClass, or In AnyNet.

Constraints

Default constraints for the Max Stub Length rule.Default constraints for the Max Stub Length rule.

  • Max Stub Length - the maximum length of stub allowed. This setting is used to test for remaining stubs of this length or longer, it does not define the drill depth used for back drilling.
    • Top Layer - back drill vias/pads, in targeted nets, from the top side of the board.
    • Bottom Layer - back drill vias/pads, in targeted nets, from the bottom side of the board.
  • Back Drill Oversize - the radial increase in size of the drill used for back drilling, over the original via/pad hole size.
    • Tolerance - allowable +ve and -ve tolerance allowed on this drill size, enter both as a positive number.

The drill depth is defined by: the sum of the layer thicknesses of all layers from the surface layer (included) through to the stop layer (not included), defined in the Drill Pair Manager.

How Duplicate Rule Contentions are Resolved

All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.

Rule Application

Batch DRC.

Refer to the Controlled Depth Drilling, or Back Drilling article, to learn more.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content